InteliDrive DCU Marine - 3.0.0 Global Guide
170
ID-SCM unit
This setpoints are available when the SCM module is configured in DriveConfig / Modules window.
Not possible to use ID-SCM when ID-RPU is used.
Setpoint group
SCM unit
Related FW
3.0.0
Range [units]
0 .. 500 [-]
Default value
0
Step
1
Comm object
10902
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM1 frequency input - SCM Freq1
value. Frequency range max. 8 kHz.
FreqRate1
Setpoint group
SCM unit
Related FW
3.0.0
Range [units]
0 .. 500 [-]
Default value
0
Step
1
Comm object
10903
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM2 frequency input - SCM Freq2
value. Frequency range max. 8 kHz.
FreqRate2
Setpoint group
SCM unit
Related FW
3.0.0
Range [units]
0 .. 500 [-]
Default value
0
Step
1
Comm object
10906
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Conversion ratio (number of pulses for increase by 1) for ID-SCM IMP 1 impulse input / SCM Imp1 value.
Frequency range max. 60 Hz.
TransferRate1
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...