InteliDrive DCU Marine - 3.0.0 Global Guide
138
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
0 .. 60 [s]
Default value
10
Step
1
Comm object
10133
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Binary input protection is activated when input is closed for longer time than BinInp delay 3. To use this filter,
binary input protection Delay must be configured in DriveConfig to BinInp delay 3.
Note:
BinInp delay x is active only for Binary inputs configured as protection and it is related to protection only.
BinInp delay x does not affect optional logical function of an input.
BinInp Delay 3