InteliDrive DCU Marine - 3.0.0 Global Guide
129
Setpoint group
Engine params
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
60
Step
1
Comm object
9815
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Under normal conditions the engine must certainly stop within this period. The period starts by issuing stop
command.
Stop Time
Setpoint group
Engine params
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
30
Step
1
Comm object
8258
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Runtime of unloaded engine to cool down engine before stopping.
Cooling Time
Setpoint group
Engine params
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
120
Step
1
Comm object
8662
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Binary output Cooling Pump is closed when engine starts and opens with AfterCoolTime delay after engine
stopping.
AfterCoolTime
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...