Setpoint group
Engine params
Related FW
3.0.0
Range [units]
0,0 .. 100,0 [%]
Default value
0,0
Step
0,1
Comm object
10010
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Offset of Idle speed in % of RPM difference between nominal and idle setpoints (Nominal RPM – Idle RPM)
–
see Requested RPM, Overload protection (PRP only) on page 27
Note:
100% of
Engine Values: Requested Speed
is the range between
Engine params: Idle RPM
and
Basic setting: Nominal RPM
.
Idle Offset
Setpoint group
Engine params
Related FW
3.0.0
Range [units]
0 .. 600 [s]
Default value
10
Step
1
Comm object
9097
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Idle time delay starts when RPM exceeds Starting RPM.
During the Idle time the Binary output Idle/Nominal is opened and after then it is closed. Binary output
Idle/Nominal opens during Cooling period (Cooling Time) again.
Idle Time