InteliDrive DCU Marine - 3.0.0 Global Guide
110
Engine commands and Statistics protection
Commands (Engine Cmd) password protection protects Start, Horn reset, Fault reset commands from
controller front panel buttons, remote displays, MODBUS line or InteliMonitor.
Selected Command password level 0, 1, 2, 3 is valid for all engine commands except of Stop. Stop command is
password protected separately by “Engine Stop” option.
Separately can be also protected statistic commands: ClearStatistics, SetSucc starts, EngRun hours,
SetUnsuc starts.
To set commands protection from DriveConfig:
1. Open DriveConfig
2. Select Commands window
3. Set Password = 0 (no protection) or level 1 or 2 or 3
Note:
Engine commands password protection works according to the description above from firmware version
ID DCU MARINE 2.1 and firmware versions of remote displays listed below. In older firmware versions “Engine
Cmd” group contains also Stop command, commands from ID-DCU MARINE local panel (buttons directly on
the controller) were not password protected in older versions.
InteliVision 5 CAN (Backlit) – from 1.3
InteliVision 8 (Marine) – depends on screen configuration in archive of ID-DCU MARINE controller. Default
archives for ID-DCU MARINE version 2.1 and higher support independent password protection of Stop
command according to description above.
Note:
All setpoints below can be modified from Remote panel or InteliMonitor as well.
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...