InteliDrive DCU Industrial 3.4.0 Global Guide
155
ID-SCM unit
This setpoints are available when the SCM module is configured in DriveConfig / Modules window.
Not possible to use ID-SCM when ID-RPU is used.
Setpoint group
SCM unit
Related FW
3.4.0
Range [units]
0 .. 500 [-]
Default value
0
Force value
Alternative config
Step
1
Comm object
10902
Related applications
AS, SS
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM1 frequency input - SCM Freq1
value. Frequency range max. 8 kHz.
FreqRate1
Setpoint group
SCM unit
Related FW
3.4.0
Range [units]
0 .. 500 [-]
Default value
0
Force value
Alternative config
Step
1
Comm object
10903
Related applications
AS, SS
Description
Conversion constant (number of pulses for one RPM) for ID-SCM RPM2 frequency input - SCM Freq2
value. Frequency range max. 8 kHz.
FreqRate2
Setpoint group
SCM unit
Related FW
3.4.0
Range [units]
0 .. 500 [-]
Default value
0
Force value
Alternative config
Step
1
Comm object
10906
Related applications
AS, SS
Description
Conversion ratio (number of pulses for increase by 1) for ID-SCM IMP 1 impulse input / SCM Imp1 value.
Frequency range max. 60 Hz.
TransferRate1
Summary of Contents for InteliDrive DCU Industrial
Page 5: ...InteliDrive DCU Industrial 3 4 0 Global Guide 5 8 2 13 Theory of binary inputs and outputs 347...
Page 29: ...InteliDrive DCU Industrial 3 4 0 Global Guide 29...
Page 97: ...InteliDrive DCU Industrial 3 4 0 Global Guide 97 8 Appendix 6 back to Table of contents...
Page 246: ...InteliDrive DCU Industrial 3 4 0 Global Guide 246 Analog inputs from J1939 configuration...
Page 263: ...InteliDrive DCU Industrial 3 4 0 Global Guide 263 6 back to List of setpoints...