![ComAp ID-FLX-Lite-PC Global Manual Download Page 31](http://html1.mh-extra.com/html/comap/id-flx-lite-pc/id-flx-lite-pc_global-manual_2638902031.webp)
InteliDrive Lite - 1.2.1 Global guide
31
permanently. Should you need to remove it, the safest way is to remove whole back cover and than remove
module manually.
For configuration of extension plug-in modules go to LiteEdit and press
button in Modify configuration
window.
4.5.2 IL-NT AOUT8
IL-NT AOUT8 is optional plug-in card. Through this card can the controller drive up to 8 VDO style
industrial/automotive gauges. This is to provide visual indication of typically ECU values without installing
additional sensors on the engine. PWM signal emulates sensor which would be typically mounted on the
engine. Sensor/gauge curve and value are configured in LiteEdit PC tool. Any analog value from the controller
may be configured to the outputs. All outputs operate as PWM signal at 1200Hz.
Examples of default analog output curves: