![ComAp ID-FLX-Lite-PC Global Manual Download Page 182](http://html1.mh-extra.com/html/comap/id-flx-lite-pc/id-flx-lite-pc_global-manual_2638902182.webp)
InteliDrive Lite - 1.2.1 Global guide
182
Setpoint group
ATT settings
Related FW
1.2.1
Range [units]
[-]
Default value
OFF
Force value
Step
[-]
Comm object
14520
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Sets ECU value Aftertreatment Regeneration Inhibit Switch (SPN 3695).
OFF – automatic filter regeneration is enabled - SPN 3695 = 00b
ON – automatic filter regeneration is inhibited - SPN 3695 = 01b
BIN – value is set by LBI Regen Inhibit
Transmitted value is set by actual level of parameter ON/OFF or by level of LBI.
Regen Inhibit
Setpoint group
ATT settings
Related FW
1.2.1
Range [units]
[-]
Default value
OFF
Force value
Step
[-]
Comm object
14521
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Sets ECU value Aftertreatment Regeneration Force Switch (SPN 3696).
OFF – automatic filter regeneration is enabled
ON – automatic filter regeneration is inhibited
BIN – value is set by LBI Regen Force
Transmitted value is activated for 5 sec. by rising edge of parameter change OFF to ON or LBI.
Regen Force
10.1.15 Group: Date/Time
Note:
Following setpoints are available from Controller and LiteEdit/InteliMonitor