InteliDrive Lite - 1.2.1 Global guide
118
Setpoint group
Basic Settings 2
Related FW
1.2.1
Range [units]
[-]
Default value
OFF
Force value
Step
[-]
Comm object
8315
Related applications
Config level
Standard
Setpoint visibility
Always
Description
Equivalent to Controller mode changes by
or
buttons.
Note:
Controller Mode change can be separately password protected.
Controller mode
Setpoint group
Basic Settings 2
Related FW
1.2.1
Range [units]
[-]
Default value
DISABLED
Force value
Step
[-]
Comm object
9983
Related applications
Config level
Standard
Setpoint visibility
Always
Description
DISABLED: Controller stays in AUT mode after Fault reset. Default state.
ENABLED: Automatic switch from AUT to MAN mode after Fault reset to avoid automatic engine start. This
function is active for Shut down protection only.
FltResGoToMAN
Setpoint group
Basic Settings 2
Related FW
1.2.1
Range [units]
0-60 [min]
Default value
15 min
Force value
Step
1 min
Comm object
10121
Related applications
Config level
Standard
Setpoint visibility
Always
Description
The display backlight is switched off after timeout.
Default value: 0 means that the display lights all the time
DispBackLightTO