![ComAp ID-FLX-Lite-PC Global Manual Download Page 104](http://html1.mh-extra.com/html/comap/id-flx-lite-pc/id-flx-lite-pc_global-manual_2638902104.webp)
InteliDrive Lite - 1.2.1 Global guide
104
Load CMP On = e.g. 2000
Load CMP Off = e.g. 2200
Speed switch
Purpose: Switch on/off some device depends on RPM level.
Description: Depends on setpoint settings the CMPH (Comparator with Hysteresis) activates/deactivates the
Binary output Load switch that switch off some device when RPM is below adjusted limit.
Input
Analog input
Binary output
Load Switch
Setpoints
Load limit:
Load CMP Input = Actual Load
Load CMP On = 2000
Load CMP Off = 2200
9.10 AUT mode: Engine regulation by RPM control -
overview
Functions below can automatically change the engine RPM to keep value measured on controller (plug-in
module) Analog input (e.g. Pressure) on adjusted level.
Functions 3 = PI loop and 4 = Comparator with Hysteresis (CMPH) are available. The function setup is done by
corresponding setpoints in
Regulator
group. This group has one PI loop and one CMPH.