ADJUSTMENTS
AND
TESTING
SIMPLA 50B-BT
SIMPLA 55BT
SIMPLA 65BT
SIMPLA 50BST
Doc. 10021896
Issued 09/2010
Ver. AB
Page
9 of 16
13.
Check the
M8 screw
that fixes the arm to the third point
allows the longitudinal movement of the base, so this can
adjust itself to the specific floor.
14.
If the base vibrates because of the brush or pad movement,
tighten the nut to further compress the spring and soften the
vibrations.
Adjusting the Washing Base
(50BST)
1.
Ensure that the brushes can be easily removed and that there
is sufficient space for their passage. If the brushes are not
clean:
•
lift the base;
•
loosen the M6 locknut;
•
loosen the
M6 screw
until there is enough space to affix
and remove the brushes from the base;
•
at the same time, check the base does not interfere with
the solution tank.
2.
Adjust the transversal inclination of the base:
•
position the machine on an even, flat floor
•
lower the base onto the floor with the brushes assembled
•
loosen the
screw and M8 nut
that fix the left lifting arm
to the base
•
rest the base on the floor so that the brushes touch the
floor simultaneously
•
tighten the M8 screw and the locknut
3.
Check the
M8 screw
that fixes the arm to the third point
allows the longitudinal movement of the base, so this can
adjust itself to the specific floor.