11
MACHINE PREPARATION
6.
Lift the batteries by means of the grips on the upper part
7.
house the batteries in the compartment, positioning the poles “+” and “-“ opposite each other
WARNING: you are advised to use airtight batteries only, to avoid the leakage
of acids!
ATTENTION: you are advised to always wear protective gloves, to avoid the
risk of serious injury to your hands
ATTENTION: You are advised to only lift and move the batteries with lifting
and transportation means suitable for the specific weight and size
7. CONNECTION OF THE BATTERIES
To connect the batteries:
1.
connect the batteries in series - using the jumper cables supplied (3) - to the poles “+” and “-“
2.
connect the battery connector cable (4) to the terminal poles “+” and “-“ to obtain a voltage of 24V
on the clamps
ATTENTION: you are advised to use airtight batteries only, to avoid the
leakage of acids!
ATTENTION: you are advised to have the electric connections made by a
qualified, COMAC-trained technician
ATTENTION: you are advised to always wear protective gloves, to avoid the
risk of serious injury to your hands
ATTENTION: you are advised to only lift and move the batteries with lifting
and transportation means suitable for the specific weight and size
8. CONNECTION OF THE ELECTRICAL SYSTEM CONNECTOR
Beneath the recovery tank there is the battery connector (2), in which the electrical system connector
(1) must be inserted.
2
1
9. RECHARGING THE BATTERIES WITH AN EXTERNAL BATTERY CHARGER (VERSIONS
WITHOUT BC)
In order not to cause permanent damage to the batteries it is essential to avoid their complete
discharge: arrange the recharge within a few minutes of the switching on of the flashing "discharged
batteries" signal.
ATTENTION: never leave the batteries completely discharged, even if the
machine is not being used. Check the battery charger is suitable for the
batteries installed, in terms of both capacity and type.
3