41
DAILY MAINTENANCE
5.
Remove the cover (4) of the cyclone filter, turning the knob (5) anti-clockwise
WARNING:
This operation must be carried out using gloves to protect against
contact with dangerous solutions.
6.
Remove the cyclone filter (6) and clean it with a cloth
43.
CLEANING THE DIESEL MOTOR'S RADIATOR
Proceed as follows in order to clean the radiator:
1.
Engage the parking brake, pressing the pedal (1)
2.
Check the main machine switch is in the “OFF-0” position. If this is not the case, turn the key by a
quarter rotation to the left.
3.
Turn the cover rotation catch (2)
4.
Using the handle (3) rotate the rear cover as far as it will go
WARNING:
This operation must be carried out using gloves to protect against
contact with dangerous solutions.
5.
Using the right tools remove the screw fixing the cable (4) stopping the rear cover rotating
WARNING
: During this operation hold onto the cord for stopping the cover
rotating, otherwise it could start twisting and get damaged.
6.
Turn the rear cover until the radiator's air passage can be accessed
5
4
6
1
2
3
4