Intelli-Connect Mobile Wireless Operator Installation Guide

144-11965 R01 July 2022

© Copyright 2022 Columbus McKinnon Corporation

Overview

The following procedure is a guide when installing a WOP-20 Wireless Operator. 
The WOP-20 can mount directly on the front of a Magnetek

®

 IMPULSE

®

•VG+ 

Series 4, IMPULSE

®

•G+ Series 4 Variable Frequency Drive (VFD), or it can be 

remote mounted on a cabinet door or panel, using a remote mounting kit. 
Installation of the WOP-20 can also work with the Magnetek IMPULSE

®

•G+ Mini 

VFD. Using the WOP-20 with the IMPULSE•G+ Mini requires a remote mounting 
kit. It is recommended for the Series 4 & G+ Mini, that the WOP is mounted on a 
cabinet door for the best wireless connectivity. Before using VFD-controlled 
equipment, read and adhere to all guidelines given in the related technical 
manuals. The user should be trained, knowledgeable, and fully aware of all 
hazards associated with crane equipment: including hoists, lifting devices, and 
electrical controls.

When installing the system, follow wiring practices provided in the VFD technical 
manuals, while following all applicable electrical codes. Remove power to the 
VFD when installing. Ensure that the mounting of all components is secure and 
follow the installation considerations and environmental conditions for the VFDs.

Hardware 

WOP-20 (114-11725) Wireless Operator

Specifications:

Operating Temperature -10°C to 50°C
Power Supply 

 4.74 to 5.25 V at 100 mA; supplied by VFD

Enclosure rating IP00
FCC and IC: Channels 1 through 11 (2142 to 2462 MHz)

S4-RMT-OPER-KIT (144-23969) Remote Mounting Hardware Kit. Includes 
mounting bracket and a 3ft and 10ft CAT5 Ethernet cable NEMA 4X/IP66 
Mounting Kit.

WARNING: If you see this symbol, be aware that safety information is 
involved.

WARNING: The wireless operator (WOP-20) should only be used with 
Magnetek variable frequency drives.
Operation that is not in accordance with VFD manuals may result in 
damage to machinery or injury of operating personnel.

• Magnetek

®

 IMPULSE

®

•VG+ and G+ Series 4

• Magnetek  IMPULSE

®

•G+ Mini

WARNING: The Wireless Operator is not to be used as a safety 
device.

WOP-20 Wireless Operator

The WOP-20 connects to the VFD via an Ethernet cable. Only one Intelli-
Connect™ Mobile App can be used to access via WiFi the VFD parameters and 
monitoring, and other users will not be able to access at same time.

Figure 1: WOP-20

Mobile App

Hardware Installation

1. Turn off power to the VFD by completely removing power to the enclosure. 

Wait 5 minutes for the VFD bus capacitors to discharge.

2. When mounting the Wireless Operator on a control cabinet door, follow the 

remote mounting instructions for cutting the necessary hole and follow 
installation instructions.

NOTE: The maximum operating distance of Wi-Fi is 100 ft (line of sight).

The Intelli-Connect™ Mobile Application can operate on Android™ 
and Apple

®

 devices. Intelli-Connect is available on Google Play or 

the Apple App Store

®

 as a free download.*

Figure 2: Panel Cutout Drawing and Side View Showing Recommended Bending 

Radius (Depth)

3. Plug one end of the Ethernet cable into the female connector on the backside of the 

WOP-20 as shown in 

Figure 3

. Use a cable long enough that will reach between 

the VFD and WOP-20. 

Figure 3: WOP-20 Cable Connection

*Android, Google Play, and the Google Play logo are trademarks of Google LLC. Apple and App Store are 
registered trademarks of Apple, Inc., registered in the U.S. and other countries.

Side view of
assembled kit

Digital operator 
cable with minimum 
bend radius

3.0" minimum

6.50

Req’d

Clearance

3.25

2.63

(6) – Ø0.20

5.50

4.00

Req’d Clearance

Enclosure Panel 

Remote
Digital Operator
Cable Connection

WOP-20 Wireless Operator Installation Guide

For Use with Intelli-Connect™ Mobile App