Please read the entire instruction manual before using the product and then 
save it for future reference. We reserve the right for any errors in text or images 
and any necessary changes made to technical data. If you have any questions 
concerning technical problems please contact our Customer Services.

Safety

•  The LEDs in this floodlight have a very intensive light output. Do not let 

children play with the floodlight. Do not look directly into the light or direct 
the light into another person’s eyes, doing so could cause eye damage.

•  Do not touch the housing or glass of the floodlight when it is switched on – 

risk of burn injury.

•  Do not install the floodlight near flammable materials or surfaces.
•  Do not cover the floodlight.
•  Do not dismantle or modify the floodlight.
•  The floodlight is suitable for use in temperatures between −20 and +50 °C.
•  The floodlight must only be used with a 230 V supply with a protective earth.
•  Any fault or damage must be repaired immediately by a qualified electrician 

before the floodlight is used.

•  Do not use the floodlight near combustible or explosive liquids, solids or gases.
•  Treat the light with care and do not subject it to shocks or impacts.
•  The floodlight must not be immersed in water or other liquid.
•  If the supply cord is damaged, it must be replaced by the manufacturer, its 

service agent or qualified persons in order to avoid a hazard.

•  The floodlight may be mounted on plasterboard, wooden or brick walls. 

It must not be mounted on walls made of or coated with flammable materials 
such as polystyrene or plastic. Do not install the floodlight on damp surfaces 
or conductive metal surfaces.

•  The floodlight must not be placed close to flammable material.
•  Ensure that the floodlight is installed in such a way that air is free to circulate 

around it.

•  Make sure that the place on the wall where you have chosen to mount 

the floodlight is free from hidden electrical conduit or plumbing before drilling 
any holes.

7.  Tilt the lamp housing to 

the desired angle and tighten 
the locking screws (1).

Installation

• 

Important:

 Read the entire instruction manual before installation. 

The installation should be carried out by a qualified electrician and conform 
to current regulations.

• 

Warning:

 Make sure that the power is turned off and that the fuse is 

removed before beginning any installation or service.

•  The floodlight must only be connected to a 230 V, 50 Hz power supply.
• 

Warning:

 Make sure that the chosen wall mounting area is free from 

electrical conduit or plumbing.

1.  The floodlight is intended for fixed installation and should be connected to 

a circuit protected by a safety device such residual current circuit breaker 
(RCCB/RCD). 

2.  Mark out the position of the mounting holes on the wall using the wall 

bracket (2) as a template. Drill holes for the mounting screws. Use suitable 
screws (and wall plugs if necessary). The floodlight must be fixed securely.

3.  Screw the floodlight onto the wall bracket. 
4.  The floodlight has 50 cm connection cable. It should be connected to 

a watertight connection box (sold separately) with a strain relief (as pictured). 

5.  Use the connection box as a template to mark out the position of 

the mounting holes. Make sure that the mounting surface is flat. Drill holes 
for the mounting screws. Use suitable screws (and wall plugs if necessary). 

6.  Connect the three wires: L Live (brown), N Neutral (blue) and Protective Earth 

(green/yellow).

Care and maintenance

•  Disconnect (isolate) the floodlight from the power supply and allow it to cool 

before cleaning.

•  Clean the light using a soft, damp cloth. Use a mild detergent. Never use 

solvents or strong, abrasive cleaning agents.

Responsible disposal

This symbol indicates that this product should not be disposed 
of with general household waste. This applies throughout 
the entire EU. In order to prevent any harm to the environment 
or health hazards caused by incorrect waste disposal, 
the product must be handed in for recycling so that the material 
can be disposed of in a responsible manner. When recycling 
your product, take it to your local collection facility or contact 
the place of purchase. They will ensure that the product is 
disposed of in an environmentally sound manner.

Specifications

Voltage 

220–240 V, 50 Hz

Power 

30 W

Light source 

COB/Bridgelux LED (non replaceable)

Luminous flux 

3000 lm

Colour temperature 

4000 K

Colour rendition 

> 80 Ra

Beam angle 

120°

Ingress protection 

IP65

Protection class 

Class 1 (this light fitting must be earthed)

Size 

175 × 164 × 65 mm

The light source contained in this luminaire shall only  
be replaced by the manufacturer or his service agent  
or a similar qualified person.

Product description

1.  Locking screws

2.  Wall bracket

3.  Lamp housing

Placement

•  The floodlight is approved for outdoor use.
•  The floodlight must not be used in explosive environments or close to chemicals.

Reviews: