Page
44
of
46
Vulcan Prime
13. Error Code Specifications
Machine Errors
Error
Code
Error Description
Remedial Action
111
Control device can't be driven
•
Reconnect USB control card
•
USB card is damaged
118
Fail
to
create
fiber
communication
Check if fiber optic cable cut/disconnected
122
System can't detect the signal
of X position encoder in reset
action and fail to reset action
•
Check emergency switch if pressed
•
Verify motion work is normal
125
Detected emergency signal
Close emergency switch, then restart software
127
Y position encoder no signal
•
Check emergency switch if pressed
•
Verify carriage motion work is normal
138
X Axis reset fault
Check emergency switch if pressed
151
No found security do
Check whether security dog is inserted in the system
152
This security dog is invalid
The security dog
doesn’t
match control hardware
154
The security dog time is
wrong!
Contact your equipment provider
155
The Security dog has expired.
Contact your equipment provider
156
The Security dog has expired
Contact your equipment provider
157
The Stage is expired
Contact your equipment provider to get new stage password
159
The security dog time is
wrong!
Contact your equipment provider
161
The authorization is inactive.
must
input
activated
password
and
restart
software!
Contact your service provider to get activated password
168
The stage password is wrong!
Contact your equipment provider to get password!
169
The new stage is expired,
continue
to
input
valid
password. Please
Contact your equipment provider to get password!
139
Y Axis Reset Fault
Verify encoder signal A and B
309
USB disconnect
Connect USB
319
Y margin is incorrect
Need to give some values instead of 0
1190
Failed to load waveform file."
"confirm
Ricoh
printhead
waveform file exist?
This can happen when new software installed. copy wf in that
folder and when error comes during initialize, go to voltage
setting and enable user pwd and select wf, load cong and apply