AuraJet Series II
Carriage Left Movement Command not Working
Reasons:
1.
Loose connection of wire between Motor and Main Board
2.
Encoder Scale is damaged
3.
Encoder Sensors are faulty
Remedial Actions:
Case 1
: Check the connection and tighten the wire.
Case 2
: Replace the Encoder Scale (Refer Case
4
of the
Print Stop During Printing
section).
Case 3
: Replace the Encoder Sensors (Refer Case
5
of the
Print Stop During Printing
section).
Bed Suction Blower not Working
Reasons:
1.
Loose connection in Pin 7 of the Main Board
2.
Blowers are faulty
3.
Supply wires to Blower having cuts
4.
Main Board is faulty
Remedial Actions:
Case 1
: Tighten the loose connection.
Case 2
: Replace Blowers, if faulty (Refer to
Case 2
of the
Ink Spot in Printing
section).
Case 3
: Replace the supply wire, if faulty.
Case 4
: Replace the Main Board.