10
Chapter 2
2.7 LED status definitions
There are several LEDs located on the main PCB which can be used for
fault reporting.
2.8 Push-button functionality
There are two push buttons located on the main PCB.
• For firmware version 3.X.X, SW1 must be clicked and hold for about 10
seconds to factory reset the panel. Be careful since all settings are deleted.
This can also be used to do a password reset after a password loss. For
previous firmware versions contact your local Signify representative for a
password or factory reset.
• SW2 is used during the production process. It is not in use.
PCB Status LED
LED color
Description
24 V power indicators
(three LEDs 24V_n)
Green
PSU active
OFF
PSU not connected or defective
5 V and 3.3 V status LED
Orange
OK, both 5 V and 3.3 V supply are present
RED
Only 5 V present, 3.3 V not present
OFF
No 5 V present
LED1
Green
Microprocessor configured and power is sent to the
RGB Light Engines
OFF
Microprocessor not configured
LED2
Green flashing
Data is being sent to RGB Light Engines, flashes in
time with animation frame rate
RED or RED flashing
Overcurrent occurred in RGB Light Engine
OFF
Luminous Textile is in stop mode
LED3
Green
Luminous Textile is in play mode
(24 V supplied to RGB Light Engine)
OFF
Luminous Textile in stop mode