Fault 

Description 

Machine condition 

Solutions 

E170 

Error door lock 

 

 

Close door completely 

 

 

 

 

Check the door lock 

 

Check the connection of the door lock 

 

Check door motor 

E180 

Door is not open 

 

The door is not open 

 

Open door with the DOOR button 

 

 

 

The mixing container is clamped 

 

Check the door lock 

 

Check the connection of the door lock 

 

Check door motor 

 

 

7.2

 

E080 MU unlocked 

 
The mixing unit was not positioned and fixed in the 12o'clock position.  
This condition occurs upon actuation of the EMERGENCY STOP button or upon interruption of the 

power supply during the mixing process. 
 
 
 

AUTO 

With the container 

clamped

  or the mixing unit 

not loaded

, the mixing unit can be automatically 

positioned and fixed with the help of 

Button I (Auto)

 

 
 
 

MANU 
With the mixing container unclamped

, the mixing unit must be positioned manually. 

Upon actuation of Button III (MANU), the door can be opened by pressing the DOOR button. 
 
 
Remove mixing unit from the mixing space and fix mixing unit manually in 12o'clock position 
 
 
Quit manual positioning by pressing the E button  
 
 

 

MU UNLOCKED 

 
 

Press Button 

for positioning 

AUTO 

 

MANU 

 

MU UNLOCKED 

 
 

Press DOOR 

for opening Door 

 

 

 

 

MU UNLOCKED 

 
 

 

wait for lock MU 

 

MU UNLOCKED 

 
 

MU locked 

Close Door 

Press E to quit 

 

MU UNLOCKED 

 
 

Press Button 

for positioning 

AUTO 

 

MANU 

 

Summary of Contents for VISCO 550

Page 1: ...Version 1 1 17 Instructions Biaxial Mixer VISCO 550 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Page 2: ...VISCO 550 Collomix GmbH 2 Version 1 1 17...

Page 3: ...ransport rollers 10 5 4 Mains connection 10 5 5 Trial run 10 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the mixing cycle 12 6 5...

Page 4: ...1 17 1 Layout Drawings 1 1 Machine components Machine components 1 Machine legs 5 Manual door release 2 Sliding door 8 Control panel CSE 3 Main switch and DC fuse 7 Lower clamping plate 4 Emergency S...

Page 5: ...N the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Factory settings 4 00 Minute Button II Mixing cycle II Factory settings 6 00 Minute Button III Mixing...

Page 6: ...e corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures ATTENTION...

Page 7: ...ating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Saf...

Page 8: ...bvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorized modifica...

Page 9: ...re taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can reduce residual risks 4 Equipment Description The biax...

Page 10: ...e legs 1 5 3 Transport rollers The mixer is equipped with two transport rollers on the bottom of the housing These transport rollers can be made to protrude out of the mixing compartment by turning a...

Page 11: ...mixing vessels To place the container proceed as follows Unlock and open the door by pushing the DOOR button Unlock the lower clamping table 7 by pressing the locking lever 8 to the left and pulling i...

Page 12: ...done working switch the machine off at the mains 3 6 6 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pr...

Page 13: ...ntainer is defect Container is unstable Check clamping pressure if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary La...

Page 14: ...upon interruption of the power supply during the mixing process AUTO With the container clamped or the mixing unit not loaded the mixing unit can be automatically positioned and fixed with the help o...

Page 15: ...he machine from the mains by pulling out the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 4 Fuses on the device 7 4 1 Device fuse If line voltage is avai...

Page 16: ...h dry run ball bearings If you clean the machine with a high pressure washer the lubricant is washed out from the ball bearings and they run try Never clean the machine with a high pressure washer or...

Page 17: ...safety equipment and electrical equipment is to verify and document after the repair Only use original spare parts Do not modify or change safety related parts Any additional components added may not...

Page 18: ...nt any damages through outside impacts during storage If necessary use cardboard and other packaging material Secure the machine against unintentional tilting and instability 9 2 Disposal The transpor...

Page 19: ...fuse 10 AT Line fuse 16 A C RCD Typ B Speed of mixing unit 630 rpm Mixing weight max 12 5 kg Container height 90 300 mm Container diameter max 300 mm Ambient temperature 5 30 C Machine weight 189 kg N...

Page 20: ...VISCO 550 Collomix GmbH 20 Version 1 1 17 10 2 Dimensions...

Page 21: ...rmation from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 2016 06 01 Alexander Essing Managing Director Manufacturer Collomix GmbH Daimlerstr 9 85080...

Page 22: ...VISCO 550 Collomix GmbH 22 Version 1 1 17...

Page 23: ...Collomix GmbH VISCO 550 Version 1 1 17 23...

Page 24: ...VISCO 550 Collomix GmbH 24 Version 1 1 17 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Reviews: