ROTA X.40
Collomix GmbH
12
Version 1.1-20
6.3
Starting the mixing cycle
The mixing cycle can only be started after the door is closed.
Push buttons I, II, or III to start the mixing process. The corresponding mixing times are shown on the
LD display above the keypad.
The mixing container is clamped into the machine and the mixing process is started. The remaining
mixing time is displayed during the mixing process.
6.4
Ending the mixing cycle
After the selected time is over
The mixing process is automatically stopped. The mixing unit is moved to the 12 o'clock position
and opens automatically. The door is opened by spring force, and the container can be removed.
If necessary, unlock and open the door
⑧
by pushing the
DOOR
button.
Before the selected time is over
The mixing process can be stopped early by pushing the E-button.
6.5
End of work
When the machine is not in use, the door should be kept closed.
When done working, switch the machine off at the mains switch
⑤
.
6.6
EMERGENCY STOP switch
In dangerous situations, the machine can be turned off with the EMERGENCY STOP switch
⑥
.
Reset the EMERGENCY STOP switch
The EMERGENCY STOP switch must be reset by hand.
Rotate the red control element clockwise.
Confirm the message in the display by pushing the E-button.
DANGER
Danger of death by dangerous voltage
There is a residual electrical energy in lines and equipment after the EMERGENCY STOP switch is
used. The EMERGENCY STOP switch does not disconnect the machine from the mains voltage.
•
If maintenance or repair work is carried out on the machine, always unplug the power cord.
After reset of the EMERGENCY STOP switch, the mixing unit must be manually turned into 12 o’clock
position in order to release the mixing container. Please follow therefore the instruction under