5.5

 

Trial run 

A trial run with an empty mixing container must be conducted when first starting the machine or after 

maintenance and repair work in order to check the proper function of the machine. 

 

WARNING 

Risk of injury due to protruding parts 

Parts may protrude from the equipment. 

 

Always work diligently on the equipment and in close proximity of the equipment. 

 

If the machine is not used and turn it off on the main switch. 

 

6.

 

Operation 

Prior to working with the machine, check all parts for their proper condition and function. Do not start 

the machine with defective or missing parts.  
Check all safety-relevant structural components of the machine for proper function before starting it. 

Any defective or damaged parts must be replaced by qualified personnel prior to starting to work with 

it. 

 

6.1

 

Switching on the machine 

The machine is turned on using the main switch 

. After an automatic initialisation, clamping plates 

② and ③ are moved apart a

nd and the door is opened by spring force. On the display 

 is shown 

START.

 

Any errors detected during initialisation are shown in text form on the display. 

6.2

 

Load a container 

Only use sufficiently stable and tight-closing vessels for mixing. In case of doubt, consult the 

manufacturer of the mixing vessels.

 

To place the container, proceed as follows: 

 

If necessary, unlock and open the door 

 by pushing the 

DOOR

 button. 

 

Observe the weight and size limits of the mixing vessel. Never overload the machine! 

 

Place the container centrically on the lower clamping plate 

. The handle of the container shall 

be backwards to the built-in handle fixation. In case the built-in handle fixation is not working, 

please use a tensioning rubber or an adhesive tape to prevent the handle from hurling around 

during the mixing. 

Never mix a container without proper fixation of the handle.

 

 

Use only undamaged containers, never stack containers! 

 

A suitable centering ring is necessary if oval containers are to be mixed! 

 

Several identical containers can be mixed at the same time. Pay attention to a symmetric 

arrangement of the containers on the mixing plate. 

 

 
 
 
 
 
 
 
 

 

Place containers always in the centre. 

          

 

 

 

Do not stack containers!

 

 

Securing the handle with 

a rubber band

 

Summary of Contents for ROTA X.40

Page 1: ...Version 1 1 20 Instructions Biaxial Mixer ROTA X 40 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch ...

Page 2: ...ROTA X 40 Collomix GmbH 2 Version 1 1 20 ...

Page 3: ...ent 10 5 2 Set up the equipment 10 5 3 Transport rollers 10 5 4 Mains connection 10 5 5 Trial run 11 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the mixing cycle 12 6 5 End of work 12 6 6 EMERGENCY STOP switch 12 7 Errors and Troubleshooting 13 7 1 Possible errors 13 7 2 E080 MU unlocked 14 7 3 Unlock door manually 15 7 4 Fuses...

Page 4: ...ne components Machine components Power supply and AC fuse Door Lower clamping plate Rubber band for handle fixation Upper clamping plate Loading shelf Manual door release Cleanout Main switch and DC Fuse Machine feet EMERGENCY STOP Switch Transport rollers Control unit ...

Page 5: ... E OPEN the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Factory settings 1 00 mins Button II Mixing cycle II Factory settings 1 00 mins Button III Mixing cycle III Factory settings 1 00 mins The specified mixing times are factory settings and may vary by customer ...

Page 6: ...if death or severe physical injuries is the result of not paying attention to the corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures ATTENTION This signal word is used if slight physical injuries occur from not paying attention to the corresponding precautionary ...

Page 7: ...before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Safety Information The basic safety information of this Chapter is supplemented by precise warnings in further chapters of the Operating Instructions 3 2 Intended Use The biaxial mixer is intended to mix Colours Colour gra...

Page 8: ...nformation installation operation servicing and maintenance set up and malfunctions WARNING Danger of injury through improper modifications Hazards exist through unauthorized modifications to the system and the use of third party spare parts Use only original spare parts and accessories of the manufacturer Do not change add to or retrofit the system without the consent of the manufacturer 3 4 Qual...

Page 9: ... the mixing vessel is released Never operate the machine if the machine door is damaged 3 5 3 EMERGENCY STOP Switch In emergencies the EMERGENCY STOP switches to halt the machine if needed 3 6 Residual Risks If all precautions are taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can reduce residual risks 4 Eq...

Page 10: ...chine with a spirit level Adjust any unevenness in the floor with the adjustable levelling feet Secure three of the four machine feet with the lock nut Then fine adjust the fourth machine foot To do this perform a test run with heavy containers while adjusting the fourth levelling feet until the best possible alignment of the machine was found Secure the fourth levelling feet after the adjustment ...

Page 11: ...pened by spring force On the display is shown START Any errors detected during initialisation are shown in text form on the display 6 2 Load a container Only use sufficiently stable and tight closing vessels for mixing In case of doubt consult the manufacturer of the mixing vessels To place the container proceed as follows If necessary unlock and open the door by pushing the DOOR button Observe th...

Page 12: ...d early by pushing the E button 6 5 End of work When the machine is not in use the door should be kept closed When done working switch the machine off at the mains switch 6 6 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch Reset the EMERGENCY STOP switch The EMERGENCY STOP switch must be reset by hand Rotate the red control element clockwi...

Page 13: ...fect Container is unstable or pre damaged Check clamping pressure and if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary Latching pin released Check the lead connector to the switch of the mixing unit lock The switch of the mixing unit lock is defective E080 Mixing Unit unlocked Latching pin blocked The mixing unit ...

Page 14: ...P button or upon interruption of the power supply during the mixing process AUTO With the container clamped or the mixing unit not loaded the mixing unit can be automatically positioned and fixed with the help of Button I Auto MANU With the mixing container unclamped the mixing unit must be positioned manually Upon actuation of Button III MANU the door can be opened by pressing the DOOR button Rem...

Page 15: ... the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 4 Fuses on the device 7 4 1 Device fuse If line voltage is available but the power button does not light up the cause may be a faulty device fuse The device fuse is in the mains connection on the back of the machine Only use 5x20mm 230V 10AT fuses to replace a blown fuse If the device fuse is tripped a...

Page 16: ...ugh wrong cleaning Never use solvent cleaning agents such as acetone gasoline or similar aggressive substances to clean the door window or the control panel Such substances can corrode or even destroy plastic parts Never clean the machine with a high pressure cleaner or water hose This washes out the grease lubrication of the ball bearings and promotes corrosion 8 2 Service Only qualified personne...

Page 17: ... parts are available for the device Part Article no Rubber for the handle fixation 62878 Mobilux EP2 grease 150 g 61299 Spare parts are available under www collomix de 9 Storage disposal 9 1 Storage The storage area should be cool and dry in order to prevent corrosion on the individual parts of the machine The room temperature of the storage area must be constantly above freezing Package the devic...

Page 18: ...ntainer height 70 400 mm Container diameter round max 360mm Container diameter oval max 360x359mm 1 Container type Round metal or plastic Ambient temperature 5 30 C Machine weight 152 kg 1 A suitable centering ring is necessary if oval containers are to be mixed Noise emission in accordance with 2006 42 EG Sound pressure level LpA 55dB re 20µPa Sound power level LWA 65dB re 1pW Uncertainty KpA WA ...

Page 19: ...hnical information from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 10 06 2020 Alexander Essing Managing Director Manufacturer Collomix GmbH Daimlerstr 9 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 IMPORTANT This declaration of conformity will lose its validity if any changes or modifications are made to the machine wit...

Page 20: ...ROTA X 40 Collomix GmbH 20 Version 1 1 20 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de ...

Reviews: