12 Cabling and setting up
For a trouble free operation of the Collamat 3600 following items must be observed:
Trained personnel
Ambient temperature
Absence of dirt and dust
Absence of splashing water
Installation and setting up of the installation
Installation and setting up of the Collamat 3600
Electromagnetic interferences
Safety regulations and safety requirements
12.1 Cabling
Electromagnetic interferences can lead to non repeatable and not obvious errors while label-
ling. Most times misplaced layout of the cabling, RMI and ESD interferences disturb the label-
ling. Because of this, the following rules must be observed for the cabling:
Separated mains and signal cables
Use shielded cables
All units must be grounded
Connect only devices which meet the RMI standards
Use power filters in interfered environments and interfered mains supplies
12.2 Setting up
The setting up must be done carefully by trained personnel. The following items must be
observed:
Visual check of the labeler unit
Are all electrical and mechanical units correctly attached ?
Are all connectors accessible ?
Connect the labeler to the mains and switch it on
Is the power switch illuminated ?
Turn off the labeler and unplug it
Set up the DIL-switches according to the desired mode. Motor turning direction.
Attach the goods scanner signals to the labeler
Connect the remaining units to the labeler
Connect the labeler to the mains and switch it on
Do the peripheral units work OK ?
Thread the paperweb and adjust the label scanner
Dispense a label. Is it dispensed correctly ?