7.3 Magnet adapter
Figure 28
The mains voltage must be connected inside of the flap printer or inside of the dispenser.
The factory setting of the trimmer TIME is on MINIMUM. The trimmer is used to set a delaytime
for the releasing of the magnet.
The terminals CP21 are used to connect the synchronous motor of the wrap around adapter
WARNING:
Plugging in of the LEFT or RIGHT connector of the flatcable to the wrong plug
can damage the magnet adapter board.
+12V
LSC
GND
+12V
TCY
LED
ON
OFF
DELAY
L
R
220V
220V
MAGN
MAGN
M A G N E T
Ph
N
14 Pol
RECHTS
LINKS
+12 V
LSC
GND
+12V
TCY
F1
3,15AT
FLACHKABEL
CP21
CP21
GS070D
+12V
LSC
GND
+12V
TCY
LED
ON
OFF
TIME
L
R
220V
220V
MAGN
MAGN
M A G N E T
Ph
N
14 Pol
RECHTS
LINKS
+12 V
LSC
GND
+12V
TCY
F1
3,15AT
FLACHKABEL
GS070C
5999.515-01E 12.06.2007 WM