TECHNICAL GUIDE

Echelon

MODELS: FC9T-UP

GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW TWO STAGE FURNACES

UP TO 94% AFUE

NATURAL GAS
40 - 120 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.gamanet.org.

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

246739-CTG-C-0407

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.

WARRANTY

Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.

10-year warranty on the heat exchanger in commercial appli-
cations.

5-year limited parts warranty.

FEATURES

• Two stage heating operation includes:

- Two stage gas valve
- Two stage inducer operation

• Provides increased comfort level & very quiet unit opera-

tion

• Adjustable delay timer allows two stage operation with 

single stage thermostat

• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-

tion.

• Integrated control module for reliable, economical opera-

tion.

• May be installed as either two-pipe (sealed combustion) 

or single pipe vent (using indoor combustion air)

• Top intake & vent connection allows installation in narrow 

locations.

• Electronic Hot Surface Ignition saves fuel cost with 

increased dependability and reliability.

• Induced combustion system with inshot main burners for 

quiet, efficient operation.

• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet 

blower.

• 24V, 40 VA control transformer and blower relay supplied 

for add-on cooling.

• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-

grade stainless steel.

• Timed on, adjustable off blower capability for maximum 

comfort.

• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance 

or service.

• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.

Summary of Contents for FC9T-UP

Page 1: ...operation includes Two stage gas valve Two stage inducer operation Provides increased comfort level very quiet unit opera tion Adjustable delay timer allows two stage operation with single stage therm...

Page 2: ...P IMAGE SUPPLY END 1 1 2 GAS PIPE ENTRY 7 8 JUNCTION BOX HOLE T STAT WIRING 7 8 K O CONDENSATE DRAIN 7 8 K O A 40 FRONT CABINET AND DUCT DIMENSIONS Models Nominal CFM Cabinet Size Cabinet Dimension A...

Page 3: ...MANCE DATA Models Input High Low Output High Low Nominal Airflow Cabinet Width Total Unit AFUE Air Temp Rise MBH MBH CFM In Amps F FC9T040A12UP11 40 26 38 24 1200 14 1 2 9 94 0 35 65 FC9T060B12UP11 60...

Page 4: ...d High 1565 1560 1560 1575 1545 1530 1475 1425 1365 1260 Med Low 1230 1275 1285 1300 1310 1300 1280 1245 1190 1070 Low 930 945 965 975 975 975 975 950 910 850 FC9T100C20UP11 High 2300 2210 2120 2020 1...

Page 5: ...of high velocity filters 2 Air flows above 1800 CFM require either return from two sides or one side plus bottom RECOMMENDED FILTER SIZES Input Output BTU H CFM Cabinet Size Side Return Filter in Bot...

Page 6: ...nction Light E W1 First Stage Heat G Fan G Fan Connection of the C Termainal 24 Volt Common is optional when used with batteries Thermostat Installer Setup Number 1 System Type must be set to 6 2 Heat...

Page 7: ...SG Bonnet Sensor Bonnet Sensor Optional BS Bonnet Sensor W2 Second Stage Auxiliary Heat W2 Second Stage Auxiliary Heat AUX Auxiliary Heat E W1 First Stage Auxiliary Heat E W1 First Stage Auxiliary Hea...

Page 8: ...w reduction value to airflow 0 50 to obtain actual airflow 0 58 ESP 2288 88 2197 ACCESSORIES CONCENTRIC VENT TERMINATION 1CT0302 2 1CT0303 3 For use through rooftop sidewall Allows combustion air to e...