Page 1: ... MANUAL BEFORE USING Manufactured in China For Customer Service Call Toll Free 1 855 900 2653 Coleman R and are registered trademark of The Coleman Company INC used under License 2010 The Coleman Company INC 120V AC 12V DC 1850W OPERATOR S MANUAL ...

Page 2: ...ecifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the generator unsafe THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION WE RESERVE THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME SAFETY RULES Throughout this publication and on tags and decals affixed to the gener...

Page 3: ...his poisonous gas if breathed in sufficient concentrations can cause unconsciousness or even death Adequate unobstructed flow of cooling and ventilating air is critical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST be operated outdoors This exhaus...

Page 4: ...ELING THE GENERATOR Use care when fueling the generator Only fill the fuel tank when the generator has cooled entirely Use fresh unleaded gasoline with a minimum Research Octane Number RON of 87 NOTE Do not use any gasoline containing more than 10 Ethanol NEVER fill the fuel tank with E85 or a mixture of oil and gasoline designated for two cycle engines Do not light a cigarette or smoke when filli...

Page 5: ...120V Peak Power 1 850W Rated Power 1 200W ENGINE Type single cylinder 4 stroke forced air cooling gasoline engine Displacement 79 5 cc RPM 3 600 Fuel Unleaded gasoline Oil SAE 10W 30 Oil capacity 13 5 oz 0 4 liters UNIT Fuel tank capacity 1 3 gallons 4 9 liters Gas consumption 0 286 gallons kw hour 1 08 liters kw hour Dimensions L W H 20 47 x 16 93 x 20 87 in Noise 64dB A Net weight 62 00 lbs 28 1...

Page 6: ...recautions or instructions can cause equipment damage and or serious personal injury Retain all manuals for future reference 2 Never use this generator for any application other than that specified by the manufacturer Never operate this generator under conditions not approved by the manufacturer Never attempt to modify this generator to perform in any manner not intended by the manufacturer 3 For ...

Page 7: ...spark plug wire before performing any service or maintenance to the unit OPERATION PRE OPERATION 1 Check fuel level before starting your generator Always use clean unleaded mid to premium grade gasoline for best results Do not overfill and allow some space at the top of the tank for expansion We recommend that you use unleaded fuel because it produces fewer engine and spark plug deposits and exten...

Page 8: ...ide sufficient electrical current carrying capacity to be an adequate ground path 3 The other end of the ground wire must be securely fastened to an approved ground source Refer to the local regulations for ground source information If not sure of regulations or procedures obtain assistance from a qualified licensed or certified electrical technician DC APPLICATION 1 The DC output is designed for ...

Page 9: ...FF position 5 Verify that the generator has completely stopped 6 Allow the unit to cool before placing in storage LOAD AND PROTECTOR 1 Total combined load through any combination of receptacles must not exceed rated power of generator 2 Reduce load if AC protector or DC protector circuit breaker turns off Press button to reset NOTE Power draw can be calculated by multiplying volts and amps The res...

Page 10: ...oloration plug should be tan in color Check the gap it should be 4 Pour approximately one teaspoon of oil into spark plug hole 5 Pull starter cord several times to spread the oil throughout the cylinder 6 Slowly pull the starter cord until resistance is left This indicates that the piston is moving upward on the compression cycle and the intake and exhaust valves are closed The piston pushes a sma...

Page 11: ...or fill if necessary z Valve Clearance Check and adjust z 1 Fuel Line Check fuel hose for crack or damage Replace if necessary z Exhaust System Check for leakage Retighten or replace gasket and bolts z Carburetor Check choke lever operation z Cooling Fan Check for damage z Starting System Check starter operation z Air Cleaner Check and clean the element z 2 Generator Bolts Check and tighten z 1 Va...

Page 12: ...necessary 2 Engine speed is too low at full load 2 Adjust engine speed ask repair shop for help 3 Excessive load applied 3 Reduce the applied load Erratic output voltage 1 Dirty corroded or loose wiring connection 1 Referring to the wiring diagram clean and reconnect all wiring 2 Unbalanced load applied 2 Remove all loads then apply each one individually to determine which one is causing erratic o...

Page 13: ...LACK AND WHITE OSU OIL SENDING UNIT SC AUXILIARY WINDING B BLACK SP SPARK PLUG DC CHARGING WINDING GR GREEN G R GENERATOR PL PILOT LAMP R RED D1 D2 RECTIFIER REC AC SOCKET Y YELLOW AC SW AC PROTECTOR CB DC PROTECTOR B R BLACK AND RED FC FIELD WINDING ENG SW ENGINE SWITCH BL BLUE 9 ...

Page 14: ... GENERATOR EXPLODED VIEW 1 3 2 4 5 6 7 8 9 10 11 14 16 17 21 23 22 26 28 30 29 27 31 36 32 34 33 35 37 38 39 50 49 48 51 52 53 24 25 46 45 44 42 43 41 40 55 56 54 57 58 64 63 59 60 61 62 65 68 67 66 70 69 72 73 71 18 19 20 10 ...

Page 15: ...8 25 2 17 Fuel tank 1 3 gal 1 54 Petcock Install Sit 1 18 Cross Screw M6 15 2 55 Fore shroud 1 19 Wheel Subassembly 2 56 Oil inspecting top 1 20 Flange Nut M6 2 57 Circuit breaker 10A 250V 2 21 Handle Cover 1 58 AC Outlet 15A 125V 1 22 Spark plug inspecting 1 59 Control Panel 1 23 Back Shroud 1 60 Cross Screw M3 16 4 24 Cross Screw M6 25 1 61 Engine switch 1 25 Washer GB95 φ6 1 62 Self tapping Scr...

Page 16: ...sted proof of purchase and maintenance is required Engine All Components Alternator All Components NOTE For the purpose of this warranty consumer use means personal residential household or recreational use by original purchaser This warranty does not apply to units used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exis...

Page 17: ...ss warranty provided herein Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to purchaser owner ALTON INDUSTRIES ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART S AS STATED ABOVE IN NO EVENT SHALL ALTON INDUSTREIS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF ALTON INDUSTRI...