Wall Box Dimmer Module
Art.no 36-6592 Model Hytronik HD2200
Please read the entire instruction manual before using
the product and then save it for future reference.
We reserve the right for any errors in text or images
and any necessary changes made to technical data.
In the event of technical problems or other queries,
please contact our Customer Services.
Installation
Note:
• This product must only be installed by a qualified
electrician.
• Push-button switch spring sold separately.
Wiring diagram
• If the connected light was switched on when
the power was cut, the light will come back on at
the same light level as before.
• If the connected light was switched off when
the power was cut, the light will remain off when
the power is restored.
Responsible disposal
This symbol indicates that this product
should not be disposed of with general
household waste. This applies throughout
the entire EU. In order to prevent any harm
to the environment or health hazards caused
by incorrect waste disposal, the product
must be handed in for recycling so that
the material can be disposed of in a responsible
manner. When recycling your product, take it to your
local collection facility or contact the place of purchase.
They will ensure that the product is disposed of in
an environmentally sound manner.
Specifications
Rated voltage
230 V AC, 50/60 Hz
Load halogen/LED
1–200 W/1–150 W
Power factor
≥ 0.97
Operating temperature
−20 to 45 °C
Fuse
Automatic reset
Overheating protection
Automatic reset
IP rating
IP20
Size (mm)
Installation with a spring-
loaded on/off switch
Thanks to their built-in synchronisation feature, multiple
(up to 50) wall box dimmers can be controlled by the same
spring-loaded on/off switch without the need for separate
synchronisation between the wall box dimmers.
Synchronisation
1. Press and hold in the on/off switch for at least
1 second and then release it, then quick-press (for
less than 1 second) the switch again. All dimmer
modules will be switched off.
2. Press in the switch again, hold in for at least
1 second and then release. The switch modules will
now be synchronised.
Potentiometer
Installation with multiple
dimmers and spring-loaded
on/off switch
Potentiometer for adjusting
the lowest dimmer level
depending on the load.
Operating instructions
• Switch light on/off: quick-press the switch. The light
will come on with the same intensity as when it was
last used.
• Stepless dimming: hold the switch in. Every time
the switch is held in, the dimmer changes function
and alternates between raising and lowering
the light level.
Memory
The dimmer remembers the latest dimmer level setting
after a loss of power (power cut or blown fuse):