PC Remote Operation

1. From the Common menu, click

Peripheral Setting

>

PC Remote Operation

.

2. The PC Remote Operation dialog appears. Select

Standard I/F(RS232)

from the Destination I/F drop-down list.

3. Check the

Use PC Remote Operation (Ethernet)

checkbox.

4. Click the

OK

button.

Figure 2-3: PC Remote Operation Dialog

Installation and Configuration

5

Summary of Contents for VisionView

Page 1: ...VisionView Application Note Mitsubishi TouchScreenPanels 05 11 2017 Version 1 6 8 16...

Page 2: ......

Page 3: ...cument may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose nor transferred to any other media or language without the written permission of Cognex Cor...

Page 4: ...ii...

Page 5: ...peration 5 Video RGB Input 6 I F Communication Setting 7 Insert Object 8 Write to GOT 10 Configure the VisionView Application 12 License 15 License the VisionView Application 15 Emergency License 15 T...

Page 6: ...iv...

Page 7: ...VisionView VGA adapter to a Mitsubishi GT15 or GT16 series touch screen VisionView Support Cognex online support is available to assist you in using the VisionView application software For online supp...

Page 8: ...2...

Page 9: ...nit to the Mitsubishi GOT for video input The RS 232 connection to the terminal allows data points from the touch screen to be sent to and from the VisionView VGA Refer to the table below to determine...

Page 10: ...interface and communication driver for the controller to be connected Figure 2 1 Controller Setting Dialog 3 Set the Ethernet address for the connection to the correct Ethernet adapter for your system...

Page 11: ...Remote Operation 2 The PC Remote Operation dialog appears Select Standard I F RS232 from the Destination I F drop down list 3 Check the Use PC Remote Operation Ethernet checkbox 4 Click the OK button...

Page 12: ...The Video RGB Input dialog appears Configure a bit to enable the display from the VisionView VGA to appear on the terminal This can be a bit from the PLC that turns on when required or it can be a bi...

Page 13: ...cation Setting 2 The I F Communication Setting dialog appears For the Standard I F Setting specify the following for the RS232 connection n CH No 8 n Driver PC Remote Operation Serial 3 Click the OK b...

Page 14: ...he position where the bit switch should be located to complete the arrangement 3 Repeat to insert a second bit switch Figure 2 6 Switch Screen 4 Double click the first arranged bit switch to display t...

Page 15: ...A Input 7 Double click the second arranged bit switch to display the Bit Switch dialog 8 Designate the switch to enable the remote mouse operation 9 Click the OK button Figure 2 8 Bit Switch Dialog Re...

Page 16: ...ars Configure the communication settings between the GOT and the PC 3 Click the OK button Figure 2 9 Communicate Configuration Dialog 4 The Communicate with GOT dialog appears Specify the correct Comm...

Page 17: ...Video RGB checkbox 6 Check the appropriate PC Remote Operation checkbox 7 Click the GOT Write button 8 Click the Close button Figure 2 11 Communicate with GOT Dialog Video RGB Installation and Config...

Page 18: ...B mouse is connected to the VisionView VGA s USB port 2 Using the USB mouse specify the appropriate language 3 Click the OK button Figure 2 12 Language Screen 4 From the Cognex VisionView Setup screen...

Page 19: ...5 From the Settings screen click the Display Settings button Figure 2 14 Settings Screen 6 From the Display Settings screen click the Touch Screen Type button Figure 2 15 Display Settings Screen 13...

Page 20: ...hi GT15 series or GT16 series touch screen Figure 2 16 Display Settings Screen Select Touch Screen Type 8 Click the OK button to apply the settings The VisionView VGA will automatically reboot Touch s...

Page 21: ...u to operate the VisionView application for a fixed period of time without verification from Cognex There are 5 emergency licenses available for each VisionView CE based HMI panel valid for 3 days for...

Page 22: ...16...

Page 23: ...using the RGB Display Settings in the Mitsubishi GOT Utility Cannot Operate the VisionView VGA from Mitsubishi GOT Using the Touch Screen 1 Verify that the VisionView VGA and the Mitsubishi GOT are c...

Page 24: ...18...

Page 25: ......

Page 26: ...Copyright 2010 2013...

Reviews: