Terminal Block Assignments
The signal assignments for each screw terminal on the I/O module's terminal blocks are detailed in the table below.
Recommended wiring is 16 - 22 AWG, solid or stranded wire.
CAUTION
:
l
The maximum torque that can be applied to the terminal block connectors is 0.1921 Nm (1.7 in-lb). Applying
torque above this limit can damage the connectors.
l
When connecting the In-Sight 7000 series vision system to the CIO-MICRO or CIO-MICRO-CC I/O module,
the I/O module's , TRIGGER-, HS OUT 0, HS OUT 1 and HS COMMON terminals are not
supported. Do not connect wire leads from remote devices to these terminals.
Pin#
Signal Name
1
+24VDC
2
24V Common
3
T
4
TRIGGER -
5
HS OUT 1
6
HS OUT 0
7
HS COMMON
8
INPUT 7
9
INPUT 6
10
INPUT 5
11
INPUT 4
12
INPUT 3
13
INPUT 2
14
INPUT 1
15
INPUT 0
16
IN COMMON
17
OUT 7
18
OUT 6
19
OUT 5
20
OUT 4
21
OUT 3
36
Specifications