High-Speed Output Wiring
To connect to an NPN-compatible PLC input, connect one of the vision system's high-speed outputs directly to the PLC
input. When enabled, the output pulls the PLC input down to less than 3VDC.
To connect to a PNP-compatible PLC input, connect one of the vision system's high-speed outputs directly to the PLC
input. When enabled, the output pulls the PLC input up to greater than 21VDC.
To connect the high-speed outputs to a relay, LED or similar load, connect the negative side of the load to the output and
the positive side to +24VDC. When the output switches on, the negative side of the load is pulled down to less than
3VDC, and 24VDC appears across the load. Use a protection diode for a large inductive load, with the anode connected
to the output and the cathode connected to +24VDC.