Section 4: Managing Job Files
In-Sight
®
1700 Series Wafer Reader
46
To connect to an In-Sight wafer reader from the browser interface, the wafer reader's
Startup settings must be configured to automatically load the default job, or another job
that has been previously saved using the browser interface.
Advanced users may customize some cells in the spreadsheet of a browser interface-
compatible job. In general, cells may be safely added to the spreadsheet. However, the
predefined functions and formulas in the spreadsheet must not be rearranged, deleted or
otherwise changed in such a way as to break compatibility with the WAFID00.JAR Java
applet. Under no circumstance should the cells in Rows 21 through 74 ever be modified.
These rows are hidden by default.
4.2 Saving Jobs
Jobs must be saved on the wafer reader to preserve changes made to Config and
Options settings. If the job is not saved, all settings changes will be lost when a new job
is opened or the power is cycled on the wafer reader.
To save a new job:
1
Click on the
File
tab.
2
Click the
Save As.…
button.
3
Enter a new file name (do not include a directory or subdirectory) in the
Save As…
dialog. Job file names can contain up to 15 characters (the .JOB extension will be
added automatically).
4
Click
OK
to save the Current Job to a new job file, or
Cancel
.
To save changes to an existing job:
1
Click on the
File
tab.
2
Click the
Save
button.
3
Click
OK
to save the Current Job, or
Cancel
.
4.3 Opening Jobs
Only job files stored in the wafer reader’s flash memory can be opened using the browser
interface.
To Load an Existing Job from In-Sight Wafer Reader Memory:
1
Click on the
File
tab.
2
Save changes made to the Current Job, if needed.
3
Highlight a job file in the list.
4
Click the
Open
button.
5
Click
OK
in the Open File dialog to load the job, or
Cancel
.
Summary of Contents for In-Sight 1721
Page 1: ...IN SIGHT 1700 SERIES WAFER READER USER MANUAL...
Page 2: ......
Page 8: ...In Sight 1700 Series Wafer Reader vi...
Page 58: ...Section 4 Managing Job Files In Sight 1700 Series Wafer Reader 48...
Page 130: ...Section 8 Specifications In Sight 1700 Series Wafer Reader 120...
Page 136: ...Updating the Wafer Reader s Firmware In Sight 1700 Series Wafer Reader 126...
Page 140: ...Configuring Microsoft Windows Network Settings In Sight 1700 Series Wafer Reader 130...
Page 154: ...In Sight 1700 Wafer Reader Mount Conversion In Sight 1700 Series Wafer Reader 144...
Page 156: ...In Sight 1700 Series Wafer Reader www cognex com products InSight default asp Rev 16 May 2006...