![Cognex In-Sight 1450 Installation And Reference Manual Download Page 27](http://html1.mh-extra.com/html/cognex/in-sight-1450/in-sight-1450_installation-and-reference-manual_2634773027.webp)
Model 1450 I/O Expansion Module Installation & Reference
3.3.2 High-Speed Outputs
In-Sight 1000 series, 3400, 4000 series and 5000 series sensors feature two built-in, high-speed
discrete outputs. The I/O Expansion Module provides access to these outputs while providing an
additional eight general-purpose discrete outputs that can be used to trigger remote events. The
high-speed outputs are passed through the I/O module without processing.
Table 3-4: High-Speed Output Specifications
SPECIFICATION
DESCRIPTION
VOLTAGE
28V maximum through external load.
200mA maximum sink current.
OFF state leakage current 100
µ
A maximum
.
External load resistance 120 to 10K Ohms
.
CURRENT
Each line rated at a maximum 200mA, protected against over-current, short circuit, and
transients from switching inductive loads. High current inductive loads require an external
protection diode.
CAUTION
■
The In-Sight 1450 I/O Expansion 24V OUT pins are intended to supply low current in support of the
I/O lines. Do not use these pins to supply power to other devices.
■
High current inductive loads require an external protection diode.
Both of the high-speed outputs are NPN (pull-down) lines. The external load should be
connected between the output and the positive supply voltage (<28V). The outputs pull down to
0V when ON, which causes current to flow through the load. When the outputs are OFF, no
current flows through the load.
15
Summary of Contents for In-Sight 1450
Page 1: ...System D I S T R I B U T E U R C O N S E I L D E P U I S 1 9 8 5...
Page 2: ......
Page 6: ...Precautions iv...
Page 8: ...Table of Contents vi...
Page 10: ...List of Figures viii...
Page 12: ...List of Tables x...
Page 16: ...Introduction 4...
Page 32: ...Specifications 3 5 Dimensions Figure 3 5 I O Expansion Module Dimensions 20...