Ethernet M12 to RJ45 Cable (CCB-84901-y00x-xx)
The Ethernet cable provides Ethernet connection for network communications. The Ethernet cable can be connected to a
single device or provide connections to multiple devices via a network switch or router.
P1 Pin#
Signal Name
Wire Color
P2 Pin#
6
TPO+
White/Orange
1
4
TPO-
Orange
2
5
TPI+
White/Green
3
7
TRMA
Blue
4
1
TRMB
White/Blue
5
8
TPI-
Green
6
2
TRMC
White/Brown
7
3
TRMD
Brown
8
Note
: Cables are sold separately. The wiring for this cable follows standard industrial Ethernet M12 specifications.
This differs from the 568B standard.
Acquisition Trigger
The acquisition trigger input on the reader is opto-isolated. To trigger from an NPN (pull-down) type photoelectric sensor
or PLC output, connect
Common In
to +24V and connect
In 0
to the output of the photoelectric sensor. When the output
turns on, it pulls
In 0
down to 0V, turning the opto-coupler on.
To trigger from a PNP (pull-up) photoelectric sensor or PLC output, connect
In 0
to the output of the photoelectric sensor
and connect
Common In
to 0V. When the output turns on, it pulls
In 0
up to +24V, turning the opto-coupler ON.
62
Connections, Optics, and Lighting