Installing the MVS-8100D
1
24
Cognex MVS-8100D and CDC Cameras Hardware Manual
Note that after opto-isolation of the TTL signal from the MVS-8100D, the connections
are for outputs only, and are no longer bidirectional.
8.
Use your Cognex software documentation to map the signal names from Table 8
and Table 9 to the software commands that enable, disable, set, and toggle each
line.
TTL_BI_10
TT
OUT 7+
Not used
Any output
device
TTL_BI_10– OUT
7–
TTL signal from
MVS-8100D
Opto-isolated
and used as
Pin
Number MVS-8100D1
MVS-8100D2
MVS-8100D3
Table 9.
Pinout for output block of external I/O option