Otello
VariWhite
Page 1: ...Otello VariWhite ...
Page 2: ...providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly followed therefore it is absolutely necessary to keep this manual User Manual version 2 1 Edition February 2020 Serial Number Purchase date Dealer Address Suburb Country Phone Fax Otello VariWhite ...
Page 3: ...p Pag 11 6 1 Operating voltage and frequency Pag 11 6 2 Connection to mains power Pag 11 7 Control signal connections Pag 12 7 1 Control signal connection by XLR5 plugs Pag 12 8 Turning the projector on Pag 13 8 1 DMX address of the unit Pag 13 9 DMX Chart Pag 14 9 1 DMX chart 5 channels Pag 14 9 2 DMX chart 2 1 channels Pag 15 10 Display panel functions Pag 16 10 1 Quick guide to menu Pag 16 10 2...
Page 4: ...d inform them you will formally notify them in writing through registered letter Packing list Ensure the packaging contains 1 Otello VariWhite 1 Instruction manual 1 Main power plugs 2 General information 2 1 Safety informations Fire prevention 1 Never locate the fixture on any flammable surface 2 Minimum distance from flammable materials 0 5 m 3 Minimum distance from the closet illuminable surfac...
Page 5: ... is under warranty for 36 months from the purchase date against factory defections 2 Damage ought to unskillfulness inappropriate use or lack of suggested maintenance are excluded from the warranty 3 Warranty expires when the projector is opened by unauthorized personnel 4 Warranty doesn t include the replacement of the fixture 5 Serial number and model of the fixture are necessary to retrieve inf...
Page 6: ... 800 to 6 500 K Color Rendering Index CRI CRI 92 at 3 200 K CRI 95 at 5 600 K Weight 9 5 Kg 20 94 lbs Maximum ambient temperature 35 C 95 F IP rating 20 Power supply 80 264 V auto sensing 50 60 Hz Maximum current 1 13 A a 230 V 2 17 A a 115 V Power factor Cosφ 0 94 min Max power consumption 245 W Color temperature All whites from 2 800 to 6 500 K Color Rendering Index CRI CRI 92 at 3 200 K CRI 95 ...
Page 7: ...7 4 Projector dimensions 4 1 Otello 6 4 2 Otello 8 manual version manual version 266 mm 10 47 in 437 mm 17 20 in 317 mm 12 48 in 409 mm 16 10 in 315 mm 12 40 in ...
Page 8: ...8 4 3 Unit s main components Components description A Adjustable yoke B Yoke locking handle C Fresnel lens D Color frame holder A B C D ...
Page 9: ...9 4 4 Back panel description PowerCon In PowerCon Out DMX Out DMX In Display Menu button Plus button Enter button Minus button ...
Page 10: ... of the fixture 5 2 Safety chain When hanging it is recommended to use a safety chain as required by current legislation The safety chain must pass through the handles of the unit and then attached to the structure If using steel cables and chains not s production make sure they are suitable to support the weight of the unit according to normative UL ETL required the weight of 6 complete devices f...
Page 11: ...one as input and one as output which can be used to feed up to 8 at 230 V or 4 at 115 V fixtures The max absorption of Otello VariWhite is reported in the following table Otello 6 230 V 0 88 A constant during normal exercise 115 V 1 69 A constant during normal exercise Otello 8 230 V 1 13 A constant during normal exercise 115 V 2 17 A constant during normal exercise 6 1 Operating voltage and frequ...
Page 12: ...uld be carried out by a suitably qualified personnel Warning Make sure that screening and conductors are not in contact one another or with the metal housing of the connector Pin 1 and housing must never be connected to the power supply unit 7 1 Control signal connection by XLR5 plugs The digital control signal is transmitted to the projector via a two pole cable screened in according to the Inter...
Page 13: ...channels a projector thus addressed will respond to commands of channel 1 to 5 from your DMX 512 controller A second unit must be addressed as A006 a third one as A011 and so on The operation must be carried out on every Otello VariWhite which has an address different from A001 Altering the DMX address 1 Press the or button until the display shows the required DMX address The digits on the display...
Page 14: ...step stop strobe 109 110 43 43 proportional sequenced pulse effect fast closing slow opening variable speed pulsing from slow to fast 111 159 44 62 step stop strobe 160 161 63 63 proportional random strobe effect with variable speed from slow to fast 162 207 64 81 step stop strobe 208 209 82 82 proportional random strobe effect with variable speed from slow to fast 210 255 82 100 5 special functio...
Page 15: ...hannel function type of control effect decimal percentage 2 1 1 1 master dimmer proportional adjust luminous output intensity from 0 to 100 0 255 0 100 2 white tone proportional proportional value from 2 800 K to 6 500 K 0 255 0 100 ...
Page 16: ...ons of the projector so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 10 2 Rapid count Through the display panel of Otello VariWhite it is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the ...
Page 17: ...nter button it will be possible to chose among three different CCT 3 200 K 4 200 K and 5 600 K Once the CCT will be chosen you can select the percentage of the light output 3200 3 200 K 10 20 100 4200 4 200 K 10 20 100 5600 5 600 K 10 20 100 ...
Page 18: ...d Auto Fan with automatic operating speed to guarantee maximum light output in all conditions of use ideal for live events exhi bitions and architectural installations Studio mode Fan at automatic operation speed with limited speed to guarantee si lent operation of the product moderately limited light output will decrease in case of overheat ideal for broadcast or theatre ap plications Low noise T...
Page 19: ...n become active only when the DMX address selection is displayed A001 The effect of AUTO and HOLD trigger after 10 seconds of keyboard in activity To turn on the display it is enough to push a button to unlock the keyboard it is nec essary to hold any button down for a few sec onds LED Frequency It allows to set the flickering frequency from 611 to 19 000 Hz besides the default value DMX signals g...
Page 20: ...s the power supply voltage DMX Input Shows the value of the DMX channels received by the fixture on every channel that the fixture occupies on the line Rate Shows the refresh rate of the DMX signal sent by the console tEMP Temperature t LEd t brd uOLT Supply Voltage dMIn DMX input CH 1 Channel 1 CH 2 Channel 2 CH 3 Channel 3 CH 4 Channel 4 CH 5 Channel 5 rAtE DMX Rate ...
Page 21: ...r of the fixture Unit shows the overall hours of life of the fixture LED life shows the overall LED module life LED life reset shows the overall LED mod ule life currently installed Note this items can be reset in case of LED module replacement Software version Shows the software version currently installed in the fixture ALrM Alarms LEd LED Status FrE LED Frequency FAn Fan Speed HOUr Usage Hours ...
Page 22: ...ould be considered for the exclusive use of technicians and qualified personnel 10 6 Electronic alignment of the leds The display panel of Otello VariWhite allows the electronic alignment of the LEDs this procedure is performed by Coemar at the time of testing this procedure may be useful for special effects or in case of replacement of internal components PCBs LEDs etc Altering the settings made ...
Page 23: ... after 10 minutes of fixture inactivity Error code Description noal No Alarm No alarm The projector self diagnostic routine didn t find any issue DTER Data Error Data error Initial data loading has failed the projector loaded the default data settings restart the fixture again and if the error persists contact the Coemar as sistance center ADER Address Error Address error The projector does not re...
Page 24: ... source of compressed air for removing dust For the cleaning of the housing use a soft cloth and a non aggressive cleaner Check that the internal fans and heat exchanger must be perfectly clean 11 3 Periodic controls Mechanical components Check the correct working of the mechanical parts and if needed replace them Make sure the projector is not mechanically damaged If necessary replace the worn pa...
Page 25: ...llo VariWhite does not emit light Projector not powered on Make sure the power cord is plugged in or test the input voltage Wrong DMX address Check the DMX Address setting and the output signal of the controller Otello VariWhite is not responding to DMX signal DMX signal may not reach Otello VariWhite Inspect the cable connection correct poor connections or ineffi cient repair or replace damaged c...
Page 26: ...User notes ...
Page 27: ...nter for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environmental and health and promote the reuse and or recycling of materials making up the equipment Illegal disposal by the user includes the application of administrative sanctions provided by law ...
Page 28: ...ighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italy phone 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to change specifications without prior notice ...