3. Connecting 0/+10 v DC signal
manual system 6
generates from the Locking-din, 6 separate outputs variable from 0 to +10V DC, as per the international
standards for analogue output; all fixtures which accept analogue signal of this type are able to be operated from the
manual
system 6
, per their respective functions.
Connection is very simple if the fixture follows the coemar standard for analogue fixture connection, which is as follows:
Plug type 8 pin Locking din on
manual system 6
Pin 1
= 0/+ 10 V DC channel 1
Pin 2
= 0/+ 10 V DC channel 2
Pin 3
= 0/+ 10 V DC channel 3
Pin 4
= 0/+ 10 V DC channel 4
Pin 5
= 0/+ 10 V DC channel 5
Pin 6
= 0/+ 10 V DC channel 6
Pin 7
= + 20 V DC input
Pin 8
= 0V DC
If your fixture accepts the coemar standard, you may use locking0din cables which are available from your authorised
coemar
distributor:
Code: 247
(5m length)
Code: 248
(10m length)
Code: 249
(25m length)
Code: 250
(50m length)
Should you wish to order only components, the following
coemar
compnent parts are available:
ME 261
(Locking-din plug)
CV 924
(per metre screened cable 8 core Ø 0.25)
CV 4158
(per metre cable 8 core Ø 0.25)
We recommend the use of screened cable; particularly in locations where there exists the possiblity of electomagnetic interfe-
rence which may cause erratic behaviour.
The screening should always be connected to pin 8 of the locking-din plug.
Below is a typical 0/+10v DC connection between the
manual system 6
and a dimmer.
8 pin locking DIN/M
8 pin locking DIN/M
in
2
3
4
5
6
7
1
8
control output:
0/+10v
segnale di uscita: