The display panel of the
ISPOT 575 EB
allows for the electronic alignment of the projector’s motors in the optical system. This pro-
cedure is performed by
coemar
at the factory. It may be useful to perform this procedure in the case of internal components being
replaced.
Altering the factory settings may radically alter the functioning of the projector. Carefully read all of the following prior to attempt-
ing any changes.
electronic calibration
1) Press the
menu
button.
2) Press the
+
or
-
button until the display shows
RESE
(for reset).
3) Press the
enter
and
menu
buttons simultaneously and hold for at least
30"
. The motors of the unit will perform a reset and the
display will show
–- –- –- –-
for some few seconds, indicating that you have entered the electronic calibration mode:
Note
: Simultaneously pressing the
+
and
–
buttons will return the calibration value to the default value of 128.
press together to acces motors
electronic calibration procedure
enter
menu
RESE
PNAL
pan alignment
pan movement alignment
TLAL
tilt alignment
tilt movement alignment
SH R
shutter alignment
alignment of shutter right part
SH L
shutter alignment
alignment of shutter left part
C1AL
colour wheel alignment
colour wheel 1 alignment (the one nearest to the lamp)
C2AL
colour wheel alignment
colour wheel 2 alignment
FOAL
focus alignment
focusing lens alignment
G1AL
gobo wheel 1 alignment
gobo wheel 1 alignment (the one nearest to the lamp)
G2AL
gobo wheel 2 alignment
gobo wheel 2 alignment
GR1
gobos alignment
rotating gobos alignment on gobo wheel 1
(the one nearest to the lamp)
GR2
gobos alignment
rotating gobos alignment on gobo wheel 2
PRAL
prisms alignment
rotating prisms alignment
IRAL
iris alignment
iris diaphragm alignment
LEAL
lenses alignment
step zoom lenses alignment
END
end
to end the electronic motor calibration procedure and to record it
0120
0140
0120
0120
0130
0127
0121
0140
0127
0127
0125
0135
0132
es.
es.
es.
es.
es.
es.
es.
es.
es.
es.
es.
es.
es.
es.
0128
0128
0128
0128
0128
0128
0128
0128
0128
0128
0128
A001
0128
0128
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
+
/
-
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
☞
enter
0127
☞
+
/
-
AOO1
☞
menu
FUNC
☞
+
/
-
☞
+
/
-
☞
Attention!
Electronic calibration is only possible if the projector is receiving
DMX 512
signal.
Attention!
This section is reserved only for technical and specialist personnel.
23. Electronic motor alignment
English