https://codelocks.zohodesk.eu/portal/en/kb/articles/cl5500-installation-instructions
plunger. Mark the positions of the fixing screws and draw around the aperture of the strike plate. Chisel out the
aperture to 15mm (3/5”) deep to receive the latchbolt. Fix the strike plate to the surface of the frame using only
the top fixing screw. Gently close the door and check that the latchbolt enters the aperture easily, and is held
without too much ‘play’. When satisfied, draw around the outline of the strike plate, remove it and cut a rebate to
enable the strike plate to lie flush with the surface. Re-fix the strike plate using both screws.
N.B. The plunger beside the latchbolt deadlocks it to protect against manipulation or ‘shimming’. The strike plate
must be accurately installed so that the plunger CANNOT enter the aperture when the door is closed, even when
it is slammed shut.
Installation of CL5510PK
1.The position of the Codelocks CL5510 front unit on the door is determined by the position of the panic device.
2.Mark the position of the spindle hole for the panic device on both sides of the door.
3. Place the gasket against the door with the 20mm (25/32”) hole centred over the mark for spindle hole. Using
the gasket as a template mark the 3 x 8mm (5/16”) holes for the through fixing bolts. Repeat on the other side of
the door.
4. Drill the 2 x 20mm (25/32”) holes and the 3 x 8mm (5/16”) holes, drilling from both sides to avoid splintering
out the face of the door. Attach the seal and insert the spindle in the back of the keypad. Offer the lock up to the
door and feed the power cable through the door and connect the battery pack on the inside.
5. Countersink the bottom fixing hole as necessary so that the fixing bolt lies flush with the door face, underneath
the panic device. Now fit the two top fixing bolts. Using the wood screw provided, fit the battery pack on the
inside of the door.
6. Fit the lever handle to the CL5510 front unit and tighten the socket head screw in the handle. Enter the code of
the CL5510 front unit and check that the lever will turn fully.
7. Install the panic device and make sure that the Codelocks front unit will fully retract the latch or bolts.
Please note: the spindle may need to be cut to suit the door thickness and engagement with both the Codelock
and panic device.
Installing the Anti-Panic CL5520 Mortice Lock
IMPORTANT The Anti-Panic Mortice Lock has features which are not found in most locks and so it is
recommended that you familiarise yourself with them.