Administrator Guide

Phone

Enclosures

Installation | Confi guration | Operation | Troubleshooting

Summary of Contents for CB 1-e

Page 1: ...800 205 7186 www codeblue com Administrator Guide Phone Enclosures Installation Configuration Operation Troubleshooting...

Page 2: ...RD TO THIS GUIDE THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DIS CLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICU LAR PURPOSE WITH REGARD TO THIS...

Page 3: ...e Low Voltage Exploded View 13 9 How to Replace LED Light Connectors 14 10 Phone Enclosure Installation Instructions 16 11 Remote Mount Beacon Strobe Installation 17 12 S 1000 S 1050 Installation Inst...

Page 4: ...tructures The exclusive analog InterAct and VoIP speakerphones are designed for maximum reliability vandal resistance auxiliary functions mass notification control and fault monitoring and reporting c...

Page 5: ...Speakerphones require programming before operation Consult the User Guide or Admin istrator Guide enclosed with the unit or go to www codeblue com Support Downloads to read or download manuals 4 If yo...

Page 6: ...0109 Analog Surge Suppressor 41471 IP Surge Suppressor 41421 Phone Enclosures Additional Options Part Part Number Pole Mount kit 40027 Remote Mount Beacon Strobe Kit 40525 PoE Power Splitter Kit Assem...

Page 7: ...5 12V DC 1 05 12 60 0 30 24V DC 1 05 25 20 0 60 CB 5 s 5 p 24V AC 0 48 11 52 0 28 12V DC 0 67 8 04 0 19 24V DC 0 67 16 08 0 39 CB 9 s 24V AC 0 26 6 24 0 15 12V DC 0 43 5 16 0 12 24V DC 0 43 10 32 0 25...

Page 8: ...AC 1 31 31 44 0 75 12V DC 1 05 12 60 0 30 24V DC 1 05 25 20 0 60 CB 5 s 5 p 24V AC 0 48 11 52 0 28 12V DC 0 67 8 04 0 19 24V DC 0 67 16 08 0 39 CB 9 s 24V AC 0 26 6 24 0 15 12V DC 0 43 5 16 0 12 24V...

Page 9: ...0 32 0 25 CB 9 s 24V AC 0 11 2 64 0 06 12V DC 0 19 2 28 0 05 24V DC 0 19 4 56 0 11 CB 2 e 24V AC 0 29 6 96 0 17 12V DC 0 39 4 68 0 11 24V DC 0 39 9 36 0 22 CB 2 a 24V AC 0 33 7 92 0 19 12V DC 0 43 5 1...

Page 10: ...and MI 49423 USA 800 205 7186 www codeblue com GU 156 K page 10 of 32 Phone Enclosures Administrator Guide 6 Legacy Power Requirements The following power requirements include the phone enclosures and...

Page 11: ...Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com GU 156 K page 11 of 32 Phone Enclosures Administrator Guide...

Page 12: ...ents effectively by re motely controlling emergency communication devices with an easy to use Graphical User Interface GUI You also will have the ability to open gates and AED access doors turn LED be...

Page 13: ...ount Painted Assy 1 2 Standard Custom Graphic 2 3 Grounding Lug 1 4 10 24 Nylock Nut 1 5 Power 4 Connector 24V 1 DISCLAIMER Product design and component use subject to change without notice Product sh...

Page 14: ...Connectors As of 2020 Code Blue strobe area and faceplate lights come with Wago connectors These con nectors provide ease of use and a much stronger connection Below are the steps needed to change to...

Page 15: ...st tight Place small screwdriver into square hole and push down Insert cut wire into round hole and remove screwdriver Repeat on the rest of the connectors Once all connectors have been switched you a...

Page 16: ...positioned between 34 and 48 inches from grade level Consult an ADA specialist in your area to verify local and federal guidelines 2 2 Drill all marked holes 2 3 Secure the housing to the wall Four an...

Page 17: ...asten the strobe J to the round portion of the strobe bracket NOTE If the beacon strobe is mounted upside down a drain hole must be drilled into the lens to prevent it from filling with water 3 0 ATTA...

Page 18: ...RY FLASH MODE connect both YELLOW control wires together i e CLOSED ON PHOTOCELL FEATURE S 1050 MODEL The Steadyburn Mode will be ON in dark or night ambient environments and OFF in bright or daylight...

Page 19: ...wer disconnected for 20 seconds BEFORE reapplying When power is reapplied the unit will operate as programmed above NOTE If you do not leave power disconnected for 20 seconds before reapplying power t...

Page 20: ...Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com GU 156 K page 20 of 32 Phone Enclosures Administrator Guide 13 PoE Installation Instructions prior to 2020 PoE extractor...

Page 21: ...When maximum tension has been reached roll tool over buckle at same time reversing handle carefully at approximately three quarters turn to avoid breakage The band that is released will be used in th...

Page 22: ...tification and service Earlier product production may have different components and wiring connections Reference the model and serial number from the unit ID tag and contact manufacturer to confirm re...

Page 23: ...ble IP5000 Incoming POE Power Patch Cable Incoming POE To Ground 16 Phone Enclosure PoE Wiring 2020 Product wiring diagram shown reasonably represents current offering and is intended to assist in com...

Page 24: ...board or Ethernet IP Connection to LAN port if IP Controller board Reference IA4100 Admin and User Guide for programming of analog controller board Reference IP5000 Admin and User Guide for programmi...

Page 25: ...t wiring diagram shown reasonably represents current offering and is intended to assist in component identification and service Earlier product production may have different components and wiring conn...

Page 26: ...age 26 of 32 Phone Enclosures Administrator Guide 15 00 3 50 15 12 20 10 10 40 Specifications subject to change without notice or obligation on the part of the manufacturer 2 50 10 00 75 1 13 CONDUIT...

Page 27: ...eached roll tool over buckle at same time reversing handle carefully at approximately three quarters turn to avoid breakage The band that is released will be used in the bend and therefore there is no...

Page 28: ...onnections are tight and clean Verify no stains exist around gasket areas Stains indicate leaking and gasket should be replaced Verify moisture weep hole on cabinet bottom is open and unobstructed Ver...

Page 29: ...be adhered to The Surface Care Frequency table below provides general guidelines to assist in configuring a schedule Please note that the frequency of care required to guard the Code Blue unit s surf...

Page 30: ...inistrator Guide 20 Locating Unit Serial Numbers Remove the IP or Analog Phone with the special security bit The serial number will be listed on the manufacturer s label located on the backside of the...

Page 31: ...upport for this product while under warranty is available at www codeblue com support In Case of Breakdown In case of system breakdown discontinue use and contact Tech Support at ts codeblue com or ca...

Page 32: ...resources guides 8 Phone Enclosures Administrator Guide www codeblue com resources guides 9 Stainless Steel Maintenance Guide www codeblue com support 10 IA4100 Administrator Guide www codeblue com r...