background image

2

Table of Contents

Features and Benefits of the F20/25 ....................................... 3

Using Your  Remote Transmitter .............................................. 4
        Locking the Vehicle Doors
        Unlocking the Vehicle’s Driver’s Door
       Unlocking All Doors using Second Stage Unlock
        Activating Trunk Release Feature

            Personal Protection Alarm

Automatic Convenience Options ............................................ 5

System Maintenance ................................................................ 6

Changing the Remote Control Battery
Adding Remote Controls to Your System
Deleting Lost or Stolen Remote Controls from Your System

Basic Troubleshooting .............................................................. 7

Emergency Disarm Procedure ............................................ 8

Emergency Disarm Button Location

    System Layout .......................................................................... 9

    Remote Transmitter Programming ....................................... 10

Programming Selectable Options ......................................... 10

Code Alarm WarrantyPlan ..................................................... 13

11

Default settings in BOLD

OPTION

DESCRIPTION

Option Bank 0 - 3 Chirps (Learn Transmitters)

Option Bank One  - 4 Chirps (Keyless Options)

STATUS INDICATOR

1. Lock with Ignition

Doors lock when all doors are closed and

ON

OFF

ignition is turned on

2. Delayed Door Locks

3 sec. delay locking for theater dimming

ON

OFF

3. Extended Locks                               Lock duration is (1) 5 sec. or (2) 0.6 sec.                                 ON

OFF

4. Unlock with Ignition                  Doors unlock when ignition is turned off                               ON

OFF

5. Duoble Unlock Pulse                      Unit provides two pulses on each unlock                                       ON

OFF

6. Illuminated Exit

                                                                                                     ON

OFF

7. Selectable Chirps

(1) Horn Chirps 1st Press   (2) Second Press                               ON(1)

OFF(2)

8. Silent Choice

                                                                                              ON

OFF

Option Bank Two - 5 Chirps (Chirps)

1. Real Panic/Horn Pulse           (1) RPS   (2) Pulse                                                                               ON(1)

OFF(2)

2. Trunk Pulse                                    (1) 20 Seconds (2) 600ms Pulse                                                ON            OFF

3. Door Trigger Polarity

   (1)Positive (2) Negative

                                   ON(1)

OFF(2)

4. 2nd Door Unlock

  (1) Illuminated Entry (2) 2nd Door Unlock                                     ON(1)

OFF(2)

Programming Selectable Options, cont’d

Summary of Contents for F20

Page 1: ...d by accident physical or electrical abuse improper installation alteration any use contrary to its intended function unauthorized service i e service by anyone other than CODE or its authorized service personnel fire flood lightning or other acts of God Should a product be found to be defective during the warranty duration CODE will repair or replace the product or any part of the product that CO...

Page 2: ... settings in BOLD OPTION DESCRIPTION Option Bank 0 3 Chirps Learn Transmitters Option Bank One 4 Chirps Keyless Options STATUS INDICATOR 1 LockwithIgnition Doorslockwhenalldoorsareclosedand ON OFF ignitionisturnedon 2 DelayedDoorLocks 3sec delaylockingfortheaterdimming O N OFF 3 ExtendedLocks Lockdurationis 1 5sec or 2 0 6sec ON OFF 4 Unlock with Ignition Doorsunlockwhenignitionisturnedoff ON OFF ...

Page 3: ...o reset all options to factory defaults 4 Press the Arm button to turn the option on or off The vehicle status indicator on the dashboard indicates whether an option is on or off If the selected option is ON the indicator will light If the selected option is OFF the indicator will turn off Thestatus indicator willturnonoroffwhenanoptionischanged 5 When changes are complete press and release the em...

Page 4: ...cations to store transmitter codes giving it the ability to operate from up to four transmitters For proper operation a transmitter code must be stored into each memory slot When using less than four transmitters follow the suggested programming parameters One Remote Transmitter Program four 4 times Two Remote Transmitters Program each transmitter two 2 times Three Remote Transmitters Program two ...

Page 5: ... 2 3 2 4 2 7 8 9 0 1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 0 1 1 1 2 1 1 2 3 4 5 6 View from wire end IMPORTANT The module MUST be programmed before it will operate Refer to the programming instructions on pages 10 12 1 PARKING LIGHT OUTPUT WHITE 2 LOCK MOTOR OUTPUT BLUE 3 UNUSED 4 BATTERY 12V RED 5 GROUND BLACK 6 UNUSED 7 IGNITION 1 INPUT OUTPUT PINK 8 UNUSED 9 UNUSED 10 UNUSED 11 UNUSED 12 UNUSED ...

Page 6: ...all remaining remote controls available 7 Basic Troubleshooting This section outlines some of the basic issues you may experience This section outlines some of the basic issues you may experience while becoming used to the PRO F20 If you have a problem that is not covered by this section please consult your installer m o t p m y S m o t p m y S m o t p m y S m o t p m y S m o t p m y S m e l b o r...

Reviews: