Maintenance
98-137261-F
Chapter 3: Service & maintenance
25
4. Click the button
Generate Test Message
. The test message is displayed in
the SAILOR 6004 Control Panel.
5.
Change audio source
: The demodulated signal (1700 Hz +/-85 Hz)
received on 518 kHz is always present for debug on connector J9. If a
receiver is not performing as expected, change the debug audio source to
that receiver (490 kHz/518 kHz/4209.5 kHz) and listen for e.g. a constant
tone, indicating a spurious on that receiver channel. The presence of a
constant tone can then be compared to the RF reception level
measurements (see page 23).
Note that changing the audio source is not saved to memory. After reboot
the 518 kHz channel is always selected.
6. To toggle the Alarm Relay click
On
and
Off
to check the connected alarm
system.
Note
Make sure that the station Z for 490 kHz is selected for
Display
. (Tap on
Control Panel
:
Menu
icon >
Filters
>
Stations
,
Display
).
Figure 26: Service Interface, toggle alarm relay
J9
Rx audio
GND
Summary of Contents for Sailor 6390 Navtex