Installation of the ACU
98-148248-C
Chapter 3: Installation
3-23
3333
Install
ation
3.4 Installation of the ACU
The following sections describe the installation and grounding of the ACU.
3.4.1 To install the ACU
To install the ACU, do as follows:
1. Slide the ACU into a 1U space in a 19” rack.
2. Mount the screws in each side through the holes in the front and fasten the screws to
the rack. Make sure that the unit is mounted securely according to the requirements for
your 19” rack.
3. Connect all cables. See
on page 4-1 for a description of the ACU
connectors.
For information about power source and power cable requirements see
3.4.2 To ground the ACU
To ground the ACU do as follows:
1. Make sure that the grounding requirements are met. See the appendix
on page C-1 for details about grounding.
2. At the ACU end, connect the shield of the ADU cable to ship ground.
3. Make sure that the rack is connected to ship ground.
4. To ensure that the ACU is grounded – also if the ADU cable is disconnected from the
ACU, connect an extra ground wire from the rack to the ground stud on the ACU. This
ground wire must be a heavy wire or braid cable with a larger diameter than the coax
cable.
Important
Make sure that the ventilation grills at the sides of the unit are not blocked.
Figure 3-23: Ground stud, ACU
Summary of Contents for SAILOR 60 GX
Page 1: ...Cobham Public SAILOR 600 VSAT Ka SAILOR 600 VSAT Ka High Power Installation manual...
Page 116: ...Software update 8 12 Chapter 8 Service 98 148248 C Figure 8 11 Verifying software update...
Page 181: ...Telenor antenna approval G 4 Appendix G Approvals 98 148248 C...
Page 192: ...98 148248 C www cobham com satcom Cobham Public...