Table 404.
0x0C - CLKDIV - Clock divisor
Clock Divisor Register
33.11.5
Table 405.
0x10 - DKEY - Destination key
Destination Key Register
33.11.6
Table 406.
0x14 - TC - Time-code
Time-code Register
31
16 15
8
7
0
RESERVED
CLKDIVSTART
CLKDIVRUN
0x0000
*
*
r
rw
rw
31: 16
RESERVED
15: 8
Clock divisor startup (CLKDIVSTART) - The value of this field is used as a clock divider during
startup (link interface is in other states than run-state). See 33.3.5 for details on how to set this
field.
Reset value taken from the CLKDIV10 input signal.
7: 0
Clock divisor run (CLKDIVRUN) - The value of this field is used as a clock divider when the link-
interface is in run-state. See 33.3.5 for details on how to set this field. Reset value taken from the
CLKDIV10 input signal.
31
8
7
0
RESERVED
DESTKEY
0x000000
*
r
rw
31: 8
RESERVED
7: 0
Destination key (DESTKEY) - RMAP destination key.
31
8
7
6
5
0
RESERVED
TCTRL
TIMECNT
0x000000
0x0
0x00
r
rw
rw
31: 8
RESERVED
7: 6
Time control flags (TCTRL) - The current value of the time-code control flags. Sent in a time-code
each time the TICKIN signal is set, or the CTRL.TI bit is written. This field is also updated with the
control flags from all received time-codes, and with the value of the TIMEIN[7:6] signals if TICK-
INRAW is asserted.
5: 0
Time counter (TIMECNT) - The current time value. Incremented, and transmitted in a time-code,
each time the TICKIN signal is set, or the CTRL.TI bit is written. This field is also updated with the
time value from all received time-codes, and with the value of the TIMEIN[5:0] signals if TICKIN-
RAW is asserted. Note that the register can be written, but that the written value is not transmitted,
since the value is incremented before transmission.