2201R Mobile Tester SCPI Reference Guide
Chapter 5 System commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
61
:SYSTem:TIME
Syntax
:SYSTem:TIME <int1>,<int2>,<int3>
Parameters
intx are three integers.
The minimum value for int1 is 0, the maximum is 23. The default value is 0.
The minimum value for int2 is 0, the maximum is 59. The default value is 0.
The minimum value for int3 is 0, the maximum is 59. The default value is 0.
Description
Sets the system time. This command uses the following format: hhmmss where
hh stands for the two digits of the current hour, using a 24 hour time format (int1),
mm gives the two digits of the current minute (int2) and,
ss represents the seconds of the system time (int3).
Query
Reads and returns the current system time in a string, using the format explained above.
Example
:SYST:TIME?
String returned: "12,56,05".
:SYSTem:SHUTdown
Syntax
:SYSTem:SHUTdown
Parameters
There are no parameters.
Description
Immediate shutdown of the 2201R.
Query
The query form of this command is not available.
Example
SYST:SHUT
Immediate shutdown of the 2201R.