
2201R Mobile Tester SCPI Reference Guide
Chapter 4 Common commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
44
*CLS
Syntax
*CLS
Parameters
There are no parameters.
Description
Resets the entire status reporting system:
The service register is cleared (all bits are set to 0).
The event status register is cleared (all bits are set to 0).
The error message queue is emptied.
All event-type registers are cleared.
Query
There is no query form of this command available.
Example
*CLS
*ESE
Syntax
*ESE <int1>
Parameters
int1 is an integer. The valid range is from 0 to 255 (8 bits).
Description
Sets the enable filter (mask) of the event status register.
int1 is the decimal representation of the binary mask.
The mask and the current contents of the event status register are ANDed. If the result is not zero, then bit 5 of the
service register is set.
Query
The query form reads out the enable filter (mask) currently set and returns its binary representation in a string.
Example
*ESE 128
As soon as power has been switched on, bit 7 (Power on) is set. ANDed with the mask 128, a binary 1 occurs and thus
bit 5 of the service register is set.