2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
254
:MEASure:EGPRs[:CONTinuous]:MULTislot:RFRX:BLER
Syntax
:MEASure:EGPRs[:CONTinuous]:MULTislot:RFRX:BLER
Parameters
There are no parameters.
Description
Measures repetitively the BLER in USF test mode for each of the time slots assigned by the 2201R using the
:CONFigure:EGPRs:MSTAtion:MSLot and :CONFigure:EGPRs:BS:MSLot[:DATA] commands respectively. The test mode
can be set by the :CALL:EGPRs:MODE command.
Notes:
The start of a new RF RX test always terminates the preceding one instantly.
The number of samples to be used for testing can be set using the :CONF:EGPRs:BLER:COUNt command.
To read out the latest measurement results, use the :FETCh:EGPRs:MULTislot:RFRX:BLER command.
Query
The query form of this command starts the measurements and — after all measurements have been completed and
all measurement results obtained — delivers a string, containing an integer number indicating the number of time
slots measured, a floating point real number giving the BLER for all slots followed by floating point real numbers giving
the BLER for individual slots, separated by commas.
Example
:MEASure:EGPRs:CONT:MULT:RFRX:BLER?
For the number of time slots set to 2, an example of the string returned is:
"2,0.2,0.0,0.2".