2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
110
:CONFigure:USSD:FNUM
Syntax
:CONFigure:USSD:FNUM
Parameters
No parameters.
Description
This command returns the value of Function Number string received from the DUT.
Query
The query form of this command returns the current value of the Function Number string.
Example
<USSDString>
Registration: **214*SI***#
De-registration: ##214*SI***#
SI = supplementary information, contains the international functional ID.
:CONFigure:USSD:FNUM?
Value returned: "**214*04921234501***#"
:CONFigure:GSMR:VGCS:UTOUinfo?
Syntax
:CONFigure:GSMR:VGCS:UTOUinfo?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
The query form of this command returns the current setting of U2U Info. The string delivered back contains any of
the following:
0 – 2201R did not receive VGCS U2U info
1 – 2201R received VGCS U2U info
2 – Timer expired on 2201R while waiting to receive VGCS U2U info.
Example
:CONFigure:GSMR:VGCS:UTOUinfo?
The value returned is: "0".