Copyright © CO2Meter, Inc. All Rights Reserved
PAGE 5 of 1
0
OLED DISPLAY
1.
Battery indicator
2.
Sensitivity mode (
S
tandard sensitivity or High
sensitivity)
3.
Display bar indicating level of CO2 leak
OPERATION
The SAN-13 is shipped with an NDIR (Non-dispersive Infrared) sensor and battery already installed.
The sensor has been calibrated and should not need recalibration for at least 3-6 months from the date
of purchase.
The SAN-13 is designed to only read CO2 (carbon dioxide). Please note, that normal atmosphere
CO2 concentrations are approximately 350~450 ppm. The device will see these background levels
but should not alarm at these levels. Please attempt to limit excess exposure to CO2 like from a car
exhaust or your breath as these could be high enough to make the SAN-13 alarm.
Instructions for finding leaks
1).
Press the power button
to turn on instrument. When the device is “on” the pump will be
flowing gas. The pump will only shut off when the device is turned off.
2).
Set the instrument to
Standard
Sensitivity (Refer to section 2. - Menu Setting).
3).
Place the tip of the leak detector probe close to the source of the suspected leak. Try to
position the probe within range of the possible leak source.