Evaluation Kit for CMX7x6x
PE0601-xxxx
©
2011 CML Microsystems Plc
7
UM0601/2
3
Quick Start
This section is divided into two sub-sections. The first is for those users who are using the
PE0601 with a PE0002 controller card and its Windows PC GUI software. The second is for users
who are using the PE0601 by itself, without a PE0002.
3.1
With PE0002
Note that the C-BUS connector, J10, and the power connector J23 are both right angle headers
and are designed to plug directly into sockets J5 (C-BUS 1 port) and J9 respectively, or sockets
J3 (C-BUS 2 port) and J7 respectively, of a PE0002.
3.1.1 Setting-Up
•
Refer to the PE0002 user manual and follow the instructions given in the quick start section.
•
Ensure the jumpers JP1 and JP2 are open circuit. The BootEn1 and BootEn2 signals are
driven from the PE0002.
The basic arrangement, when used with the PE0002, is shown below:
PE0002
PC
USB Cable
PE0601-xxxx
J23
J2
J3 or J5
C-BUS
Direct Connections
JP1/2
J8
J9 or J7
+V
J10
Power
Supply
Figure 2 – PE0601 used with PE0002
3.1.2 Operation
The Function Image
TM
(FI) must now be loaded into the CMX7x6x device. A FI is provided as a ‘C’
type header file and must be obtained from the CML Technical Portal. There are two methods
available for loading the FI:
1. Directly from a file on the PE0002 host PC to the CMX7x6x