11
Parameters
CONTROLLER DIAGNOSTIC TOOL (CDT)
Anti-Tamper
The
anti-tamper
setting defines maximum speed if the Anti-Tamper fault is triggered (e.g. controller is disconnected
from the Guardian or Visage system). These speeds can only be activated if the Control Mode option is set to 1
(Guardian/Visage) and are intended to be a deterrent. Factory default setting is 1.
• 0 = OFF; uses controller configured speed (
S1
through
S4 Fwd Speed
,
Rev Speed
and
Speed Cal
parameters)
even if the Anti-Tamper fault is triggered
• 1 = 2 mph
• 2 = 0 mph
• 3 = 7 mph
Deterrent Demo
The
deterrent demo
setting defines maximum speed of Control Mode 3.
• 0 = Controller configured speed (
S1
through
S4 Fwd Speed
,
Rev Speed
and
Speed Cal
parameters)
• 1 = 10 mph
• 2 = 7 mph
• 3 = 2 mph
Excel Braking
The
excel braking
menu item allows the user to turn this function ON or OFF. With it ON, the vehicle maintains the
regen motor braking “feel” of the Excel system. With it OFF, regen motor braking is less aggressive and the vehicle
mimics the “feel” of the IQ system.
For example:
A
Pedal Up Mode
setting of 2 = 150 amps of regen motor braking. Setting
Excel Braking
to ON
increases regen by 30 amps for a total of 180 amps and a more aggressive braking action.
WalkAway Deterrent
The
walkaway deterrent
menu item allows the user to turn this function ON or OFF.
Walkaway deterrent
is triggered by
the High Speed WalkAway fault. With it ON, the reverse buzzer will sound immediately upon the key switch being turned
OFF at speeds above 2 mph. With it OFF, the buzzer will cycle on and off at a higher frequency (7.5 Hz vs. 2.5 Hz).
Battery Type
The
battery type
menu item is intended to be used with Guardian/Visage so that the type of battery could be determined
and displayed when remotely monitoring vehicles.
Charger Control
Beep Option
The
Beep Option
controls use of the reverse buzzer to sound a confirmation that charging has started: 0 = OFF, 1
= 1 beep, 2 = 3 beeps. From the factory, the
Beep Option
will be set to 2.
AMP HOURS
Reset Trip Amp Hours
The
reset trip amp hours
menu item allows the user to reset counter to zero (0). To reset, set to ON and then
immediately back to OFF. To review or validate, proceed to Amp Hours Display on page 11-13 under the Monitor Menu.
ACCESS CODES
Code A, Code B, and Code C
The code entries are used to place the vehicle in “private speed mode”, speed setting code 4. Each vehicle has a
unique code for placing the vehicle in this mode. A vehicle programmed for “private speed mode”, speed setting 4,
Page 11-8
2019 Precedent Villager 2 Maintenance and Service Manual
Summary of Contents for Precedent Villager 2
Page 2: ......
Page 395: ...ELECTRIC MAIN HARNESS Wiring Diagrams Electric Main Harness 25...
Page 396: ...Page intentionally left blank...
Page 398: ...Page intentionally left blank...
Page 399: ...GASOLINE MAIN HARNESS Wiring Diagrams Gasoline Main Harness 25...
Page 400: ...Page intentionally left blank...
Page 402: ...Page intentionally left blank...
Page 403: ...GASOLINE ENGINE HARNESS Wiring Diagrams Gasoline Engine Harness 25...
Page 404: ...Page intentionally left blank...
Page 412: ...NOTES...
Page 413: ......
Page 414: ......