background image

WARNING

DANGER

WARNING

CAUTION

NOTICE

SAFETY 

GUIDE

Carbon dioxide is known as an asphyxiant gas.  Carbon dioxide poisoning has been linked 
to various health issues, including central nervous system damage, permanent deterioration 
of respiratory functions, suffocation or even death.  If you have any health concerns that may 
be related to the Product’s use of carbon dioxide, consult your doctor before using any of the 
Products. 

• CO₂ Levels can be measured using a CO₂ Monitor.
• 5,000 PPM is the workplace exposure limit in most jurisdictions.
• Check with your local agency to verify any need for permits in your area.

To ensure safe operation, user must follow instructions closely. Necessary protocols should be followed when 
handling and operating Special Effects Equipment and their respective consumables.

• Never place objects of any kind inside barrels.
• Never aim or fire the products at any person or living thing. 
• This product is meant to be used only in well-ventilated areas.

When using the products, always follow the safety radius displayed in this manual.

Once the product is attached to the CO₂ tanks and the tanks are turned on, the product, hoses and fittings will 
be under high pressure.  Do not disconnect any fittings or hoses until the tank has been turned off, and the 
remaining gas has been cleared through the product, depleting all pressure in the system. If a leak is detected, 
cease use of the product immediately. Never stand directly over unit while under pressure. Jets should be 
mounted or fixed in a safe place.  When using Jets above ground, always use a safety cable in the event the 
Product’s mount or fixture should fail.  You must supply the safety cable(s) to use with this product.  If you are 
under 18, you should not be using this product.

Preventing Serious Injury or Death

CO2 Special Effects are to only to be used in well ventilated areas. Failure to do so may result in oxygen 
displacement.

Maintain a safe distance between Special Effects Products and audience, crew & event staff. Refer to the safety 
radius outlined in this manual.

Never aim Special Effects Products directly at any person or living thing.

Always fasten tanks to avoid tipping, rocking, or being tampered with. When feasible, keep tanks out of direct 
sunlight.

Check with officials in local jurisdiction for any permit requirements before operating Special Effects.

This icon signifies that severe 

bodily harm or death 

will

 

occur if instuctions are not 

followed.

This icon signifies that severe 

bodily harm or death 

may

 

occur if instuctions are not 

followed.

This icon signifies that mild 

to moderate injury may 

occur if instuctions are not 

followed.

This icon signifies product 

malfunction or damage may 

occur if instructions are not 

followed.

3

Summary of Contents for QUAD JET

Page 1: ...User Manual VERSION 1 0 AUG 2021...

Page 2: ...GUIDE 4 SAFETY RADIUS 4 SAFE MOUNTING 5 HARDWARE OVERVIEW 6 UNIT REAR 6 HARDWARE SPECIFICATIONS 7 CO2 REQUIREMENTS 8 CO2 SETUP 9 QUICK START GUIDE 10 HOME SCREEN 11 MODE SELECTION 11 HOME STATES 12 P...

Page 3: ...adJet in 4 channel DMX mode independent control of each output nozzle can be achieved Triggering CH 1 2 3 or all 4 channels at once will have different effect heights TIP User can also elect to use th...

Page 4: ...lubcannon com QUAD JET TRUE1 CABLE 4 CO ATTACHMENT TOOL THIS GUIDE 20 CO WASHERS 4 CO2 HOSE Four nozzle Co2 Jet 6 Edison to True1 cord Used to tighten the CGA 320 fitting to your CO2 tank A link to th...

Page 5: ...f and the remaining gas has been cleared through the product depleting all pressure in the system If a leak is detected cease use of the product immediately Never stand directly over unit while under...

Page 6: ...times while operating this product Special care must be taken when preformers are near units Always inform performers staff and event personel that may inadvertantly enter the safety radius of this p...

Page 7: ...VER mount to flown hung truss due to recoil force INVERTED MOUNTING Inverted mounting is NOT recommended Due to the large output from this unit the minimum safety radius must be followed Unless this i...

Page 8: ...Con cable DMX Standard NEUTRIK 5 Pin XLR Connectors 1 Channel All nozzles trigger as one 4 Channel Individual control of each nozzle HARDWARE OVERVIEW 2 4 INCH LCD TOUCH SCREEN 4 x CLUB CANNON BARRELS...

Page 9: ...240v AC 50 60hz DIMENSIONS 11 75 x 11 75 x 13 125 298mm x 298mm x 333mm CONSUMPTION 125W MAX Approx 25W Per Nozzle TRUSS MOUNTS 1 2 13 truss bolt required Nut pre installed in base CO2 CONSUMPTION 0...

Page 10: ...The effect works best in humid environments Anytime humidity levels are 25 or below the fog will appear noticeably thinner Use the weather app on your phone to check your local humidity level TEMPERAT...

Page 11: ...eeve and apply slight force to mate the connectors 2 Place the plastic washer inside the fitting that connects to the tank then attach the fitting Tighten with the supplied tool or any adjustable wren...

Page 12: ...addressing Each set of arrows independantly controls the above digit Note Max available address on 4CH mode is 509 3 ATTACH HOSES Follow the steps outlined in CO SETUP GUIDE for proper CO2 setup Read...

Page 13: ...to setting the DMX address The main menu can be accessed by tapping on the DMX address This is the default screen that is shown when the Quad Jet is first powered on STATUS BAR INCREASE DIGIT DECREASE...

Page 14: ...he address will be displayed in red The display will dim when idle for 30 seconds with active DMX signal When DMX is being received the address will be displayed in green If screen is tapped when in i...

Page 15: ...efore purging warn anyone nearby There will be a 5 second delay after activating the purge lines feature This allows the user sufficient time to step away from the unit All valves will be opened for 1...

Page 16: ...eaks are present Ensure no particles or contaminates are present inside the female quick connector Check for any damage to black O ring Leak from tank connection Ensure a CO2 washer has been inserted...

Page 17: ...ctronic device sensitive to moisture To avoid risk of electronicshock malfunction or voidedwarranty onlyuseindryenvironments Do not operate in harsh weather conditions Do not block or insert anything...

Page 18: ...Page left blank intentionally 16...

Page 19: ...Excluding any services provided to you by the Company under a separate written agreement these Terms and Conditions constitute the entire agreement between you and the Company regarding the use of th...

Page 20: ...CONTACT US 856 Ricardo Ct San Luis Obispo CA 93401 888 804 8175 info clubcannon com www clubcannon com CLUB CANNON 2021 18...

Reviews: